Visual abstractsVisuals
ResearchJournal of Infectious Diseases · Nov 26, 2025

[18F]Fluorodeoxyglucose Positron Emission Tomography for Diagnosis and Monitoring of Acute Staphylococcus aureus Vascular Graft Infection in a Rat Model

Faddy E, Johansen MI, Gadeberg C, Meyer RL, Østergaard L, Bay-Richter C, et al
Infectious DiseaseBasic science

Study type: Laboratory or animal research: results may not apply to people yet.

Read the full paper free at PubMed Central ↗

Abstract

Objectives Vascular graft or endograft infections (VGEIs) pose a detrimental complication when using vascular grafts and are challenging to diagnose and treat. This study examined the progression of infection and the antimicrobial response in VGEI using [18F]Fluorodeoxyglucose (chemical name, 2-Deoxy-2-[18F]fluoroglucose) (FDG) positron emission tomography (PET), ex vivo bacterial quantification, and histology in a VGEI rat model. Methods In this experimental study, 97 male Sprague-Dawley rats had a polytetrafluorethylene graft surgically implanted in the carotid artery. The graft was either preinoculated with Staphylococcus aureus, S. epidermidis, or saline. Up to 31 days after surgery, rats were FDG-PET-scanned. Subsequently, they were killed, and the implants were retrieved for analysis. A subgroup of infected rats received daptomycin and rifampicin from days 20 to 29. Results Tracer uptake around the implant, measured by maximum standardized uptake value (SUVmax), declined over time in all groups. Between groups, SUVmax was highest in untreated S. aureus-infected rats. When comparing antibiotic-treated and uninfected rats by day 31, there was no difference in SUVmax, although the treated rats were still infected. Histology revealed widespread inflammation by day 10 in S. aureus-infected rats, which decreased by days 20 and 31 with encapsulation of the infection, alongside increased plasma interleukin-10. Conclusions FDG-PET differentiated untreated S. aureus-infected rats from uninfected ones but failed to monitor infection progression, as SUVmax declined over time despite a constant bacterial load. FDG-PET could not distinguish between uninfected rats and those with suppressed infection, likely due to reduced inflammation and encapsulation of the infection.

Topics

Animals; Fluorodeoxyglucose F18; Staphylococcal Infections; Positron-Emission Tomography; Rats, Sprague-Dawley; Male; Rats; Staphylococcus aureus; Disease Models, Animal; Prosthesis-Related Infections; Blood Vessel Prosthesis; Anti-Bacterial Agents

DOI: 10.1093/infdis/jiaf594 · PubMed: 41296646

Spotted a mistake? Suggest a correction

More in Infectious Disease

Clin Microbiol Infect · Nov 21, 2026 · Research · Infectious Disease

Only ENDOVAL score met threshold for predicting in-hospital mortality in infective endocarditis

Clin Microbiol Infect · Nov 21, 2026 · Review · Infectious Disease

Rapid susceptibility testing methods shorten time to results for new antibiotics

Clin Infect Dis · Nov 20, 2026 · Research · Infectious Disease

Survey defines clinical work standards in academic infectious diseases

Euro Surveill · Nov 20, 2026 · Research · Infectious Disease

Leptospirosis hospitalisation rate decreased in Guadeloupe between 2005 and 2023

Euro Surveill · Nov 20, 2026 · Research · Infectious Disease

Forty-nine dengue cases reported in Italy after holiday site exposure