Randomized trialThe Lancet Digital Health · Mar 23, 2024

A deep-learning model for intracranial aneurysm detection on CT angiography images in China: a stepwise, multicentre, early-stage clinical validation study

Hu B, Shi Z, Lu L, Miao Z, Wang H, Zhou Z, et al
Digital Health & AINeurosurgeryAdult
Stepwise, multicentre, early-stage clinical validation studyBenefit found
Can a deep-learning model improve intracranial aneurysm detection on computed tomography angiography images?
Who
Clinicians reviewing computed tomography angiography images · Eight Chinese hospitals
Compared
0.789Clinicians without AI (95% CI 0.780 to 0.799)
0.858Clinicians with AI (95% CI 0.850 to 0.866)
Main outcome
Area under the receiver operating characteristic curves
Result: 0.858 (95% CI 0.850 to 0.866) vs 0.789 (95% CI 0.780 to 0.799)
Bottom line: A deep-learning model significantly improves clinician diagnostic performance and acceptance for detecting intracranial aneurysms on computed tomography angiography.
Funded by: National Natural Science Foundation of China
Lancet Digit Health · 2024-03-23Download image

Clinical question: Can a deep-learning model improve intracranial aneurysm detection on computed tomography angiography images?

Read the full paper free at the publisher ↗

Abstract

Background Artificial intelligence (AI) models in real-world implementation are scarce. Our study aimed to develop a CT angiography (CTA)-based AI model for intracranial aneurysm detection, assess how it helps clinicians improve diagnostic performance, and validate its application in real-world clinical implementation. Methods We developed a deep-learning model using 16 546 head and neck CTA examination images from 14 517 patients at eight Chinese hospitals. Using an adapted, stepwise implementation and evaluation, 120 certified clinicians from 15 geographically different hospitals were recruited. Initially, the AI model was externally validated with images of 900 digital subtraction angiography-verified CTA cases (examinations) and compared with the performance of 24 clinicians who each viewed 300 of these cases (stage 1). Next, as a further external validation a multi-reader multi-case study enrolled 48 clinicians to individually review 298 digital subtraction angiography-verified CTA cases (stage 2). The clinicians reviewed each CTA examination twice (ie, with and without the AI model), separated by a 4-week washout period. Then, a randomised open-label comparison study enrolled 48 clinicians to assess the acceptance and performance of this AI model (stage 3). Finally, the model was prospectively deployed and validated in 1562 real-world clinical CTA cases. Findings The AI model in the internal dataset achieved a patient-level diagnostic sensitivity of 0·957 (95% CI 0·939-0·971) and a higher patient-level diagnostic sensitivity than clinicians (0·943 [0·921-0·961] vs 0·658 [0·644-0·672]; p<0·0001) in the external dataset. In the multi-reader multi-case study, the AI-assisted strategy improved clinicians' diagnostic performance both on a per-patient basis (the area under the receiver operating characteristic curves [AUCs]; 0·795 [0·761-0·830] without AI vs 0·878 [0·850-0·906] with AI; p<0·0001) and a per-aneurysm basis (the area under the weighted alternative free-response receiver operating characteristic curves; 0·765 [0·732-0·799] vs 0·865 [0·839-0·891]; p<0·0001). Reading time decreased with the aid of the AI model (87·5 s vs 82·7 s, p<0·0001). In the randomised open-label comparison study, clinicians in the AI-assisted group had a high acceptance of the AI model (92·6% adoption rate), and a higher AUC when compared with the control group (0·858 [95% CI 0·850-0·866] vs 0·789 [0·780-0·799]; p<0·0001). In the prospective study, the AI model had a 0·51% (8/1570) error rate due to poor-quality CTA images and recognition failure. The model had a high negative predictive value of 0·998 (0·994-1·000) and significantly improved the diagnostic performance of clinicians; AUC improved from 0·787 (95% CI 0·766-0·808) to 0·909 (0·894-0·923; p<0·0001) and patient-level sensitivity improved from 0·590 (0·511-0·666) to 0·825 (0·759-0·880; p<0·0001). Interpretation This AI model demonstrated strong clinical potential for intracranial aneurysm detection with improved clinician diagnostic performance, high acceptance, and practical implementation in real-world clinical cases. Funding National Natural Science Foundation of China. Translation For the Chinese translation of the abstract see Supplementary Materials section.

Abstract reproduced under the article’s CC BY NC ND licence.

Topics

Humans; Intracranial Aneurysm; Computed Tomography Angiography; Artificial Intelligence; Prospective Studies; Deep Learning; Cerebral Angiography

DOI: 10.1016/S2589-7500(23)00268-6 · PubMed: 38519154

Cite this article

Hu B, Shi Z, Lu L, Miao Z, Wang H, Zhou Z. A deep-learning model for intracranial aneurysm detection on CT angiography images in China: a stepwise, multicentre, early-stage clinical validation study. Lancet Digit Health. 2024. doi:10.1016/S2589-7500(23)00268-6

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Meta-analysis · J Neurointerv Surg · Nov 14, 2022 · Neurosurgery, Digital Health & AI

Detection of cerebral aneurysms using artificial intelligence: a systematic review and meta-analysis

Randomized trial · Eur Radiol · Sep 19, 2024 · Radiology & Imaging, Digital Health & AI

Deep learning reconstruction and low voltage protocols reduce radiation and contrast dose in coronary scans

Research · Eur Radiol Exp · Mar 16, 2026 · Radiology & Imaging, Pulmonology

Deep learning-based identification of chronic pulmonary embolism on CTPA: a regional lung analysis using multiplanar MIP images

Research · Eur Radiol · Apr 20, 2026 · Radiology & Imaging, Cardiology

Detection of calcified plaques: comparison between coronary CT angiography and thin-slice non-contrast CT with deep learning-aided image registration

Research · Eur Radiol Exp · Nov 13, 2026 · Radiology & Imaging, Digital Health & AI

Deep learning tools were associated with higher image quality in ultra-high-resolution coronary scans