Visual abstractsVisuals
ResearchOphthalmology Science · May 12, 2026

A Framework for Standardized Manual Segmentation and Measurement of Uveal Melanoma on Ultrasound

Chadwick WF, Ganesh S, Dadzie AK, Lokesh Y, Alahmadi R, Yao X, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose To develop and validate a standardized manual segmentation protocol for delineating choroidal tumors on B-scan ultrasonography to improve measurement reproducibility in uveal melanoma. Design Cross-sectional reproducibility study. Participants Two hundred seventy five ultrasound images of melanocytic choroidal tumors obtained from a single tertiary ocular oncology clinic. Methods Two independent reviewers performed manual segmentation using an iterative, consensus-based annotation workflow, adjudicated and validated by an ocular oncologist. Inter-reviewer and intrareviewer agreement was assessed using surface-based metrics including average symmetric surface distance (ASSD), 95th percentile Hausdorff distance (HD95), and normalized surface distance (NSD). The resulting layer segmentations were used to derive geometric tumor measurements including tumor height and largest basal diameter (LBD) measured using both a 1-chord and arc-length approach. Main outcome measures Inter-reviewer and intrareviewer agreement (ASSD, HD95, and NSD) and mean absolute error for derived tumor thickness and LBD measurements. Results The consensus protocol identified 4 consistent anatomical boundaries: inner retina, inner tumor margin, outer tumor margin, and outer sclera. Average inter-reviewer agreement across all classes was high, with ASSD: 0.14 mm, HD95: 0.49 mm, and NSD at 0.2 mm: 81%. Most disagreement occurred at the scleral interface and in cases with shadowing, artifact, subretinal fluid, or mushroom shape. Derived tumor measurements demonstrated low mean absolute errors of 0.21 mm, 0.59 mm, and 0.72 mm for thickness, 1-chord LBD, and arc-length LBD, respectively. Conclusions A standard, operationalized segmentation protocol enables reproducible boundary delineation on ophthalmic ultrasound and provides a foundation for consistent tumor measurement and future computational automation. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101229 · PubMed: 42293347

Cite this article

Chadwick WF, Ganesh S, Dadzie AK, Lokesh Y, Alahmadi R, Yao X. A Framework for Standardized Manual Segmentation and Measurement of Uveal Melanoma on Ultrasound. Ophthalmol Sci. 2026. doi:10.1016/j.xops.2026.101229

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine eye drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds developed to assess visual field loss severity in retinitis pigmentosa patients