Visual abstractsVisuals
ResearchJournal of Otolaryngology - Head & Neck Surgery · May 8, 2026

A Hand-Guided Robotic Drill for Vestibular Implant Surgery-Feasibility of Preventing Membranous Labyrinth Rupture

Stultiens JJA, Du X, Waterval JJ, Pérez Fornos A, Guinand N, van de Berg R
ENT (Otolaryngology)SurgeryAdult
Read the full paper free at PubMed Central ↗

Abstract

ImportanceProgress in vestibular implantation offers hope for patients with bilateral vestibulopathy. However, surgically opening the semicircular canals risks breaching the membranous labyrinth, which may induce sensorineural hearing loss. A robotic drill sensing force and torque might prevent membranous labyrinth rupture.Primary objectiveTo assess the feasibility of force- and torque-based automatic cessation in a hand-guided robotic drill for fenestrating the bony semicircular canals without rupturing the membranous labyrinth.Secondary objectiveTo fit an electrode dummy through the fenestrations.DesignFeasibility study using human cadaveric temporal bones.SettingLaboratory.ParticipantsTen formalin-fixed human temporal bones.InterventionAfter performing a cortical mastoidectomy and skeletonizing the semicircular canals, a hand-guided robotic drill was used to drill 2 fenestrations in each semicircular canal. A silicone electrode dummy was inserted through each fenestration.Main outcome measuresProportion of fenestrations with intact membranous labyrinth, as evaluated with a surgical microscope. Proportion of fenestrations allowing electrode insertion without additional manipulation.ResultsA total of 60 fenestrations were made in 30 semicircular canals from 10 temporal bones. Technical issues related to drill bit fixation occurred in 6 fenestrations. The remaining 54 fenestrations were all made without visible damage to the membranous labyrinth. In 81% of these fenestrations (44/54), the electrode could be advanced without requiring additional manipulation. The technical issue was related to improper alignment of the drill bit, leading to incorrect force and torque sensing.ConclusionsForce- and torque-based automatic cessation in a hand-guided robotic drill is feasible for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. However, improved burr fixation is required for consistent and reliable performance.RelevanceThe investigated approach holds potential to improve safety and precision in semicircular canal surgery, such as vestibular implantation. This may expand treatment options for patients with residual inner ear function.

Topics

Humans; Feasibility Studies; Robotic Surgical Procedures; Cadaver; Semicircular Canals; Temporal Bone; Ear, Inner; Mastoidectomy

DOI: 10.1177/19160216261433549 · PubMed: 42099194

Cite this article

Stultiens JJA, Du X, Waterval JJ, Pérez Fornos A, Guinand N, van de Berg R. A Hand-Guided Robotic Drill for Vestibular Implant Surgery-Feasibility of Preventing Membranous Labyrinth Rupture. J Otolaryngol Head Neck Surg. 2026. doi:10.1177/19160216261433549

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Laryngoscope · Apr 14, 2026 · Research · ENT (Otolaryngology)

Micro-CT Evaluation of Robot-Assisted Insertion of CI632 Implant in Human Cadaveric Temporal Bones

Laryngoscope · Apr 27, 2026 · Research · ENT (Otolaryngology)

Integrating Augmented Reality Into Otologic Cadaveric Surgical Training

Head Neck · Jul 14, 2026 · Research · ENT (Otolaryngology)

Submental Approach Robotic-Assisted Neck Dissection (SARAND) for Minimally Invasive Bilateral Neck Dissection: A Feasibility Cadaver Dissection Study

Ann Surg · Aug 19, 2026 · Research · Surgery

Tele-Robotic Surgery for Combat Casualty Care: Proof of Feasibility

Otolaryngol Head Neck Surg · Aug 3, 2026 · Randomized trial · ENT (Otolaryngology)

Training on identical 3D-printed bone models improved skill retention compared to using varied models