Randomized trialJournal of Plastic, Reconstructive & Aesthetic Surgery · Apr 25, 2024

A randomized intraindividual comparative study evaluating the effects of two ultrasound-assisted liposuction devices on the abdomen

Márquez-Gutiérrez EA, Tamez-Pedroza L, Morales-Naya ED, Vélez-Palafox M, Cuartero-Castro G, Zacaula-Juárez N, et al
Plastic & Reconstructive SurgeryRadiology & ImagingAdult
Read the full paper free at the publisher ↗

Abstract

Background Ultrasound-assisted liposuction (UAL) has become popular because of its favorable outcomes in fat emulsification, blood loss reduction, and skin tightening. This study aimed to compare the effects of two UAL devices on the abdomen by assessing postsurgery skin biomechanical properties. Methods This single-blind, prospective study (2020-2022) involved 13 liposuction procedures performed on patients without chronic diseases. Each patient's abdomen was divided vertically from the xiphoid to the perineum. Vibration amplification of sound energy at resonance (VASER)-assisted liposuction (Solta Medical, Inc., Hayward, CA) was performed on one half, while the other half underwent liposuction with high-frequency ultrasound energy (HEUS)-assisted technology. Skin biomechanical measurements, including distensibility, net elasticity, biological elasticity, hydration, erythema, melanin, and skin firmness, were taken at 12 and 24 months postsurgery, focusing on the anterior abdomen, 8 cm to the right and left of the umbilicus. Results Analysis of the above skin biomechanical measurements revealed no significant differences between the HEUS and VASER devices, except for skin firmness, which showed a notable increase following HEUS surgery. Patient-perceived clinical differences were assessed via nonvalidated questionnaires, revealing no distinctions between devices. Conclusion Biomechanical skin results post-UAL surgery with these devices on the abdomen were not significantly different, although HEUS revealed increased skin firmness. This suggests that HEUS-assisted technology, akin to other devices, is a viable option for UAL procedures.

Topics

Humans; Lipectomy; Female; Prospective Studies; Adult; Single-Blind Method; Middle Aged; Male; Abdomen; Ultrasonic Therapy; Skin Physiological Phenomena

DOI: 10.1016/j.bjps.2024.04.040 · PubMed: 38733713

Cite this article

Márquez-Gutiérrez EA, Tamez-Pedroza L, Morales-Naya ED, Vélez-Palafox M, Cuartero-Castro G, Zacaula-Juárez N. A randomized intraindividual comparative study evaluating the effects of two ultrasound-assisted liposuction devices on the abdomen. J Plast Reconstr Aesthet Surg. 2024. doi:10.1016/j.bjps.2024.04.040

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Aesthet Surg J · Jun 3, 2025 · Randomized trial · Plastic & Reconstructive Surgery

Reflective Blankets vs Electric Warming in Preventing Hypothermia During Liposuction: A Randomized Controlled Trial

Aesthet Surg J · Sep 6, 2024 · Meta-analysis · Plastic & Reconstructive Surgery

The Effect of Tranexamic Acid Administration During Liposuction on Bleeding Complications and Ecchymosis: A Systematic Review

Aesthet Surg J · Oct 15, 2025 · Meta-analysis · Plastic & Reconstructive Surgery Visual abstract

Characteristics and Complications of Combined Implant and Lipoplasty Techniques in Primary Gluteal Augmentation: A Systematic Review and Meta-Analysis

Aesthet Surg J · Apr 2, 2024 · Meta-analysis · Plastic & Reconstructive Surgery

Risks and Complications Rate in Liposuction: A Systematic Review and Meta-Analysis

Aesthet Surg J · Jan 30, 2025 · Meta-analysis · Plastic & Reconstructive Surgery

Aesthetic Efficacy and Safety of Combined Microfocused Ultrasound With Visualization and Calcium Hydroxylapatite Treatment: A Systematic Review of Human Evidence