Abstract

Background Quantitative neuromuscular monitoring is crucial to ensure patient safety when using neuromuscular blocking agents. Although historically considered as the research standard for neuromuscular monitoring, currently, no certified mechanomyography device is available for routine clinical use. This study aimed to investigate noninferiority in precision of a newly developed mechanomyography (TOF3D mechanosensor; MIPM, Mammendorf, Germany) compared with electromyography. Methods We conducted a prospective, interventional, single-centre agreement study comparing electromyography and mechanomyography in 33 anaesthetised adult patients. Devices were randomly installed on opposite arms. Train-of-four (TOF) ratios were measured beginning before administration of rocuronium 0.45 mg kg-1 i.v. until spontaneous recovery and after additional administration of sugammadex 2 mg kg-1 i.v. The primary endpoint was precision using the repeatability coefficient at baseline and full recovery. Precision of the TOF ratio measurement was assumed noninferior if the repeatability coefficient did not exceed a margin of 0.01. Results Mechanomyography had higher repeatability coefficients than electromyography at all measured TOF intervals. Mechanomyography was partially noninferior to electromyography because the 95% confidence interval of the median difference between TOF ratios of both techniques (0.039 [0.007 to 0.042]) covered the acceptable margin during baseline, but not after recovery to TOF ratio >0.9 (0.052 [0.047 to 0.076]). Conclusions The TOF3D mechanosensor was not less precise than electromyography during baseline. Better hand fixation must be achieved to improve precision mechanomyography. Clinical trial registration EUDAMED (CIV-23-06-043334); ClinicalTrials.gov (NCT06230653).

Topics

Adult; Aged; Female; Humans; Male; Middle Aged; Electromyography; Myography; Neuromuscular Blockade; Neuromuscular Monitoring; Neuromuscular Nondepolarizing Agents; Prospective Studies

DOI: 10.1016/j.bja.2025.10.067 · PubMed: 41506970 · Registered: NCT06230653

Spotted a mistake? Suggest a correction

More in Anesthesiology

Br J Anaesth · Nov 20, 2026 · Research · Anesthesiology

Postoperative delirium accelerates brain ageing by six months

Br J Anaesth · Nov 20, 2026 · Research · Anesthesiology

Vaping-related disorder linked to higher postoperative respiratory complications risk

Br J Anaesth · Nov 20, 2026 · Research · Anesthesiology

Low perfusion index during surgery linked to higher 30-day mortality rates

Br J Anaesth · Nov 17, 2026 · Research · Anesthesiology

Ephedrine and phenylephrine increase human myometrial contractility ex vivo

BJA Open · Nov 13, 2026 · Meta-analysis · Pediatric · Anesthesiology

Effects of propofol- or sevoflurane-containing anaesthesia on auditory brainstem responses in children: a systematic review