Abstract
Background
Eloesser flap reconstruction remains challenging because prior thoracic surgery, local vasculature disruption, and chronic infection can limit reconstructive options. Reconstruction must restore chest wall mechanics, address bronchopleural fistulae, obliterate pleural dead space, and provide durable coverage. Standardized strategies for reconstruction of Eloesser flap defects remain limited. Methods
We reviewed the clinical experience at a single institution in Eloesser flap reconstruction and integrated these findings with a literature review and anatomic considerations. A reconstructive algorithm was developed based on the presence of bronchopleural fistulae, pleural dead space, and defect size. Reconstructive options included omental and muscle flaps for dead space obliteration and musculocutaneous flaps for durable soft-tissue coverage. Results
Four patients underwent Eloesser flap reconstruction. The proposed algorithm prioritizes bronchopleural fistulae management before chest wall closure. When residual pleural dead space was present, vascularized tissue was used for obliteration, with the serratus anterior muscle preferred for its thin profile, pliability, and favorable intrathoracic reach. For larger defects, double opposing latissimus dorsi musculocutaneous flaps provide soft-tissue coverage and facilitate epithelialization. This approach enabled simultaneous management of pleural dead space and chest wall defects while preserving thoracic function. Conclusions
Reconstruction of Eloesser flap defects requires individualized consideration of fistula status, dead space, defect size, and tissue availability. Our experience supports an approach incorporating vascularized muscle and musculocutaneous flaps, with the serratus anterior offering a reliable option for intrathoracic dead space obliteration. Larger studies are needed to validate this algorithm and define long-term functional outcomes.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training