MicroShunt implantation had a lower probability of surgical success than trabeculectomy in glaucoma patients
Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma: One-Year Results from a 2-Year Randomized, Multicenter Study
Why it matters: It was unknown whether the MicroShunt device is as effective as trabeculectomy for controlling intraocular pressure in patients with primary open-angle glaucoma.
- The study randomized 395 patients to receive a MicroShunt and 132 patients to undergo trabeculectomy, a traditional filtering surgery, for primary open-angle glaucoma.
- At one year, the probability of surgical success was 53.9% for the MicroShunt group compared to 72.7% for the trabeculectomy group.
- The trabeculectomy group had a lower mean intraocular pressure of 11.1 ± 4.3 mmHg compared to 14.3 ± 4.3 mmHg in the MicroShunt group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Baker ND, Barnebey HS, Moster MR, Stiles MC, Vold SD, Khatana AK. Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma: One-Year Results from a 2-Year Randomized, Multicenter Study. Ophthalmology. 2021. doi:10.1016/j.ophtha.2021.05.023