Visual abstractsVisuals
ResearchOpen Forum Infectious Diseases · Jan 29, 2026

Accuracy and Acceptability of the VISITECT CD4 Advanced Disease Test Compared With the PIMA CD4 Test at the Point of Care as Part of the Advanced HIV Disease Care Package: A Mixed-Methods Study

Gils T, Misra S, Madonsela T, Pita TP, Bosman S, Ayakaka I, et al
Infectious DiseaseAdult
Read the full paper free at PubMed Central ↗

Abstract

Background CD4 testing is the first step of the advanced human immunodeficiency virus (HIV) disease (AHD) care package. The semiquantitative VISITECT CD4 Advanced Disease test (VISITECT; AccuBio) is increasingly used but has variable reported performance. We compared its diagnostic accuracy and acceptability with that of the PIMA CD4 test (PIMA; Abbott) at the point of care within the AHD care package. Methods A mixed-methods study was embedded in a community-based tuberculosis case-finding trial in South Africa. Following a VISITECT batch recall (April 2023), a sample of trial participants with HIV underwent VISITECT and PIMA testing in parallel on a single venous blood sample. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. We conducted in-depth-interviews with people with HIV (PWH), focus group discussions with nurses, and participant observations with nurse-PWH pairs. Results Among 609 included PWH, 76 (12.5%) were found to have CD4 cell counts ≤200/µL with VISITECT versus 28 (4.8%) with PIMA. The sensitivity, specificity, PPV, and NPV for VISITECT, compared with PIMA, were 89.3% (95% confidence interval, 71.8%-97.7%), 91.2% (95% CI, 88.6%-93.4%), 32.9% (95% CI, 22.5%-44.6%) and 99.4% (95% CI, 98.4%-99.9%), respectively. Three VISITECT results (0.05%) were false-negative (CD4 cell counts, 16/µL, 82/µL, 175/µL) and 51 (8.4%) were false-positive (median CD4 cell count, 563/µL [interquartile range, 382-739/µL]). PWH and public sector nurses believed that point-of-care CD4 tests improve access to CD4 cell counts. Study nurses preferred PIMA to VISITECT in terms of accuracy, duration, user-friendliness, and yielding of a numeric CD4 result. Conclusions Compared with PIMA, VISITECT had good diagnostic accuracy but low PPV and was less acceptable to study nurses. The role of VISITECT should be further evaluated.

DOI: 10.1093/ofid/ofag043 · PubMed: 41725708

Spotted a mistake? Suggest a correction

More in Infectious Disease

Clin Microbiol Infect · Nov 21, 2026 · Research · Infectious Disease

Only ENDOVAL score met threshold for predicting in-hospital mortality in infective endocarditis

Clin Microbiol Infect · Nov 21, 2026 · Review · Infectious Disease

Rapid susceptibility testing methods shorten time to results for new antibiotics

Clin Infect Dis · Nov 20, 2026 · Research · Infectious Disease

Survey defines clinical full-time equivalent in academic infectious diseases

Euro Surveill · Nov 20, 2026 · Research · Infectious Disease

Leptospirosis hospitalisation rate decreased in Guadeloupe between 2005 and 2023

Euro Surveill · Nov 20, 2026 · Research · Infectious Disease

Forty-nine dengue cases reported in Italy after holiday site exposure