Visual abstractsVisuals
ResearchClinical Chemistry · Jun 19, 2026

Accuracy-Based Proficiency Testing Surveys for Testosterone Provide Important Information About Measurement Accuracy and Its Impact on Patient Care

Straseski JA, Vesper HW, Long TA, Horowitz GL
Pathology & Laboratory MedicineAdult
Read the full paper free at the publisher ↗

Abstract

Background Many clinical guidelines include laboratory measurements, which require accuracy across laboratories. This study aimed to determine whether testosterone measurements by a small subset of labs using commutable specimens could be used as a surrogate marker of accuracy across widely used testing platforms. It also assessed the frequency of categorization errors that might occur near the male hypogonadal threshold and whether performance on traditional surveys predicted performance using commutable specimens. Methods Three presumed commutable samples were created using human serum; Sample A was provided in a routine mailing of a traditional (non-commutable) proficiency testing survey (reference value 234 ng/dL, n = 1431 laboratories), Samples B and C were part of a routine mailing of an accuracy-based survey (reference values 277 ng/dL and 196 ng/dL, n = 118 and 138 laboratories). Results The overall mean bias from the reference method value was less than 2% for all 3 samples, but individual peer (method) group biases ranged -16% to +15%. Five percent of reported values for Sample A were above the hypogonadal threshold (264 ng/dL), falsely indicating "healthy state" (peer group miscategorization ranged 29% to 0%). Conversely, 44% of results for Sample B were below the hypogonadal threshold, falsely indicating hypogonadism (peer group miscategorization ranged 100% to 0%). Comparison of results between non-commutable and commutable specimens indicated that bias was different in direction and magnitude for 3 of 6 method groups. Conclusions Assessing performance using commutable specimens reported by smaller numbers of users may serve as a reasonable approximation for performance of method groups in general.

Topics

Humans; Testosterone; Male; Laboratory Proficiency Testing; Reference Values; Laboratories, Clinical; Reproducibility of Results; Hypogonadism

DOI: 10.1093/clinchem/hvag068 · PubMed: 42319155

Spotted a mistake? Suggest a correction

More in Pathology & Laboratory Medicine

ResearchMod Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine

Tumor-selective overexpression of five receptors found in triple-negative breast cancer

Intra-Patient Cell-Surface Receptor Normalization Refines TNBC Biomarker Profiling for Precision Oncology

ResearchMod Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine

CD40 expression differentiates Hodgkin lymphoma from anaplastic large cell lymphoma

CD40 expression is highly sensitive and specific for differentiating between classic Hodgkin lymphoma and ALK-negative anaplastic large cell lymphoma

ResearchMod Pathol · Nov 12, 2026 · Pathology & Laboratory Medicine

Deciphering Benign and Malignant Perineuriomas: A Comparative Epigenomic and Genomic Study With Hybrid and Malignant Peripheral Nerve Tumors

ResearchPediatricMod Pathol · Nov 12, 2026 · Pathology & Laboratory Medicine

Pediatric-type Follicular Lymphoma Shows Unique Immunogenetic Features With Lack of Acquired N-glycosylation Sites

ResearchMod Pathol · Nov 12, 2026 · Pathology & Laboratory Medicine

Pilomatrix-like high-grade endometrioid carcinomas have distinct molecular features

Pilomatrix-like High-Grade Endometrioid Carcinoma in the Female Genital Tract: A Single-Institution Clinicopathologic Analysis of 15 Cases