Visual abstractsVisuals
ResearchThe Lancet Regional Health – Southeast Asia · Apr 24, 2026

Accuracy of a smartphone-based 3D imaging tool for height measurement and stunting detection among children 24-59 months of age in Nepal: a validation study

Mukherjee R, Kaushik S, Salah H, Gupta AK, Sharma D, Kahraman M, et al
PediatricsRadiology & ImagingNutritionPediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Detection of stunting in young children using traditional anthropometry has been a challenge at the community level especially in resource-constrained settings. We evaluated the performance of Child Growth Monitor (CGM), a smartphone-based 3D depth-imaging application, for screening of stunting, and height measurement among children (24-59 months of age) in Nepal. Methods At four health-posts in Rautahat district, Nepal, in October 2024, we conducted cross-sectional validation study comparing CGM's stunting detection against gold standard (manual measurement) and prospective reliability assessment with repeat measurements, four days apart. Eight trained enumerators collected data using calibrated height boards and CGM app. Validity was assessed through sensitivity, specificity and accuracy, reliability through intraclass correlation coefficients (ICC) and Technical Error of Measurement (TEM). Pitman's test evaluated variance. Bias was assessed using Bland Altman statistics. Findings 310 children were recruited, with analyses based on paired subsets (n = 261). Manual measurements identified 36% as stunted, while CGM detected 31·8%. CGM demonstrated 84·0% sensitivity, 98·2% specificity, 96·3% positive and 91·6% negative predictive values, and 93·1% accuracy. For height measurement, the ICC for intra-rater and inter-rater reliability were 0·990 (n = 76) and 0·992 (n = 75) respectively, with intra- and inter-rater TEM of 0·5 cm. Inter-method TEM was 0·7 cm. Pitman's test was significant; Bland-Altman showed mean bias of 0·3 cm. Interpretation CGM demonstrated accuracy and reliability for field-based stunting detection among children belonging to 24-59 months of age in Nepal. Future research on its use in younger children (6-24 months) and diverse settings will enable its integration into routine growth monitoring. Funding This study was funded by the German Federal Foreign Office as part of the overall funding for the development of Child Growth Monitor app.

DOI: 10.1016/j.lansea.2026.100774 · PubMed: 42080151

Spotted a mistake? Suggest a correction

More in Pediatrics

BMJ Paediatr Open · Nov 19, 2026 · Research · Pediatric · Pediatrics

Joint agency response investigations helped identify new causes of death in children with learning disabilities

Arch Dis Child · Nov 19, 2026 · Research · Pediatric · Pediatrics

Seventy-seven percent of referrals confirmed female genital mutilation in young girls

BMJ Paediatr Open · Nov 18, 2026 · Review · Pediatric · Pediatrics

Framework proposed for caring for children on the move with rights-based approach

BMJ Paediatr Open · Nov 17, 2026 · Meta-analysis · Pediatric · Pediatrics

Prenatal paracetamol exposure may slightly increase autism spectrum disorder risk

BMJ Paediatr Open · Nov 17, 2026 · Research · Pediatric · Pediatrics

MIS-C disease severity decreased across COVID-19 waves in children studied