Achieving High Projection Without Compromise: Process Optimization of a New Resilient Hyaluronic Acid for Deep Structural Support
Abstract
Background
Traditional technology used to create cohesive hyaluronic acid (HA) injectables for aesthetic use often relies on increased HA concentration and high crosslinking to maximize strength and robustness. As a result, natural HA integrity may be compromised, leading to less dynamic rheology, difficulty in hyaluronidase degradation, and poor tissue integration. Objectives
The aim of this study was to demonstrate high projection capability, reversibility, and smooth tissue integration with an HA injectable gel produced from an optimized crosslinking process without high 1,4-butanediol diglycidyl ether modification. Methods
TPVM was created using optimized Preserved Network Technology (PNT+) crosslinking technology and evaluated against the existing US-approved and Conformité Européenne (CE)-marked resilient hyaluronic acid (RHA) fillers (RHA1-RHA4 in Europe, RHA Redensity, RHA2-3, and RHA Dynamic Volume in the United States). Assessments included physicochemical properties, rheology, injectability, hyaluronidase degradation, physician-rated injection ease across 3 indications, and long-term tissue integration in minipigs up to 156 weeks. Results
Despite a modification degree of 2.1%, among the lowest in the marketed fillers, TPVM achieved the highest elastic modulus (G' = 629 ± 8 Pa), linear viscoelastic region (454 ± 15 Pa), and resistance to compression force (10.5 ± 0.1 N). Injectability was rated "very easy" or "easy" in over 94% of cases across midface, chin retrusion, and jawline indications. Like all RHA gels, TPVM reached complete hyaluronidase degradation within 30 min. Histological evaluation at 52 and 156 weeks confirmed smooth tissue integration and progressive gel degradation with no encapsulation or persistent inflammation. Conclusions
Optimized PNT+ crosslinking technology decouples gel mechanical performance from the degree of chemical modification, enabling superior projection capacity while preserving enzymatic reversibility and tissue integration.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training