Aerosol containment device design considerations and performance evaluation metrics

Jones RM, Andrus N, Dominguez T, Biggs J, Hansen B, Drews FA
Emergency MedicineAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Spurred by the Coronavirus infectious disease 2019 pandemic, aerosol containment devices (ACDs) were developed to capture infectious respiratory aerosols generated by patients at their source. Prior reviews indicated that such devices had low evidence of effectiveness, but did not address how ACDs should be evaluated, how well they should perform, nor have clearly defined performance standards. Towards developing design criteria for ACDs, two questions were posed: 1) What characteristics have guided the design of ACDs? 2) How have these characteristics been evaluated? Methods A scoping review was performed consistent with PRISMA guidelines. Data were extracted with respect to general study information, intended use of the device, device design characteristics and evaluation. Results Fifty-four articles were included. Evaluation was most commonly performed with respect to device aerosol containment (n = 31, 61%), with only 5 (9%), 3 (6%) and 8 (15%) formally assessing providing experience, patient experience and procedure impact, respectively. Nearly all of the studies that explored provider experience and procedure impact studied intubation. Few studies provided a priori performance criteria for any evaluation metric, or referenced any external guidelines by which to bench mark performance. Conclusion With respect to aerosol containment, ACDs should reduce exposure among HCP with the device compared with the absence of the device, and provide ≥90% reduction in respirable aerosols, equivalent in performance to N95 filtering facepiece respirators, if the goal is to reduce reliance on personal protective equipment. The ACD should not increase awkward or uncomfortable postures, or adversely impact biomechanics of the procedure itself as this could have implications for procedure outcomes. A variety of standardized instruments exist to assess the experience of patients and healthcare personnel. Integration of ACDs into routine clinical practice requires rigorous studies of aerosol containment and the user experience.

More on this topic

COVID-19

Subject terms

Humans; Respiratory Aerosols and Droplets; COVID-19; Personal Protective Equipment; Intubation, Intratracheal; Equipment Design

DOI: 10.1016/j.ajem.2022.11.007 · PubMed: 36435005

Cite this article

Jones RM, Andrus N, Dominguez T, Biggs J, Hansen B, Drews FA. Aerosol containment device design considerations and performance evaluation metrics. Am J Emerg Med. 2022. doi:10.1016/j.ajem.2022.11.007

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Randomized trial · Am J Emerg Med · Jan 4, 2022 · Emergency Medicine, Critical Care

Video laryngoscope improved first attempt intubation success compared to Macintosh blade during cardiac arrest

Randomized trial · Scand J Trauma Resusc Emerg Med · Jan 10, 2022 · Emergency Medicine

Personal protection equipment does not impair attention or dexterity in paramedics during life support

Meta-analysis · Am J Emerg Med · Jan 27, 2021 · Emergency Medicine, Infectious Disease

Intubation rate was 28% among COVID-19 patients receiving awake prone positioning

Randomized trial · Am J Emerg Med · Nov 10, 2025 · Emergency Medicine, Cardiology

Additional tasks like family presence and protective equipment increased workload during simulated cardiac arrest resuscitation

Randomized trial · Scand J Trauma Resusc Emerg Med · Jun 29, 2021 · Emergency Medicine, Cardiology

Three mechanical chest compression devices were compared for use during alpine mountain rescue transport