ResearchJournal of the American College of Cardiology · Aug 19, 2026

AI-ECG Detection of Structural Heart Disease in the Community Setting: Transportability and Spectrum Effects in the PREVUE-VALVE Study

Poterucha TJ, Hughes JW, Brener MI, Chuang ML, Hamid NB, Snyder C, et al
CardiologyAdult
Same trial (NCT05357404)

Papers we list that report this registered trial, oldest first. Read a secondary analysis alongside the main results.

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Artificial intelligence (AI) diagnostic models are typically developed in hospital-based populations enriched for disease prevalence and severity, where distinctions between health and disease are pronounced. When deployed in community-dwelling populations with lower prevalence and milder phenotypes, these distinctions may become less well-defined, raising questions about transportability and the impact of disease spectrum on model performance. Objectives The purpose of this study was to evaluate how differences in disease spectrum influence the transportability of AI-based diagnostic models into community-dwelling populations, using artificial intelligence electrocardiogram analysis (AI-ECG) for structural heart disease (SHD) as a test case. Methods EchoNext is an AI-ECG model trained in a multicenter, hospital-based cohort to detect SHD. We evaluated its performance in PREVUE-VALVE (Age and Sex-Specific PREValence of AcqUirEd VALVular Heart DiseasE Study), a community-based study of individuals aged 65 to 85 years undergoing in-home ECG and transthoracic echocardiography. Performance was assessed using area under the receiver operating characteristic curve (AUC) and predictive value and compared with derivation and external hospital-based cohorts, using propensity matching to account for differences in disease prevalence and case mix. Subgroup analyses were performed in clinically relevant populations. Results Among 3,000 PREVUE-VALVE participants, 2,402 met criteria for analysis. Compared with hospital-based cohorts, PREVUE-VALVE had lower SHD prevalence (8% vs 43%), less severe disease, and a shift in phenotype, including more moderate tricuspid regurgitation and less systolic heart failure. Consistent with these differences, model discrimination was lower in PREVUE-VALVE than in the hospital-based cohort (AUC: 71% [95% CI: 66%-76%] vs 83% [95% CI: 82%-83%]). Propensity matching attenuated but did not eliminate this difference, while performance was similar across external hospital-based cohorts, supporting disease spectrum and clinical context as key drivers. Performance was modestly better in PREVUE-VALVE subgroups with higher SHD prevalence and greater disease severity, such as individuals with an abnormal ECG (AUC: 79% [95% CI: 75%-83%]) or impaired health status (AUC: 76% [95% CI: 70%-82%]). Conclusions In a community-dwelling population with lower disease prevalence and milder phenotypes, AI-ECG performance was attenuated relative to hospital-based cohorts, driven by differences in disease spectrum. These findings underscore the impact of both disease prevalence and case mix on AI performance and highlight the importance of model evaluation within intended use populations. (Age and Sex-Specific PREValence if AcqUirEd VALVular Heart DiseasE; NCT05357404).

More on this topic

AI in medicine

Subject terms

Humans; Electrocardiography; Female; Male; Artificial Intelligence; Aged; Aged, 80 and over; Heart Diseases; Echocardiography

DOI: 10.1016/j.jacc.2026.06.013 · PubMed: 42615442 · Registered: NCT05357404

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Poterucha TJ, Hughes JW, Brener MI, et al. AI-ECG Detection of Structural Heart Disease in the Community Setting: Transportability and Spectrum Effects in the PREVUE-VALVE Study. J Am Coll Cardiol. 2026;88(7):752-764. doi:10.1016/j.jacc.2026.06.013

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Systematic review · Clin Microbiol Infect · Jun 23, 2021 · Infectious Disease, Cardiology

Cardiac sequelae after coronavirus disease 2019 recovery: a systematic review

Guideline · Eur Heart J · Apr 12, 2026 · Pediatric · Cardiology, Pediatrics

European experts propose first specific cardiac screening guidelines for athletes under 16

Research · Br J Sports Med · Feb 12, 2026 · Orthopedics & Sports Medicine, Cardiology

Outcomes of cardiac screening in elite para-football players in the United Kingdom

Randomized trial n = 1,232 · Nat Med · Sep 2, 2024 · Cardiology, Obstetrics & Gynecology

AI digital stethoscope detected more pregnancy-related heart issues than usual care

Research · J Am Heart Assoc · Apr 28, 2026 · Cardiology, Digital Health & AI

Artificial Intelligence-Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic Value