Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗
Top Emergency Medicine studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Background/ aim To reduce the risk of fire, the ERC resuscitation guidelines recommend removing all oxygen-delivery devices at least 1 m away from the patient's chest prior to defibrillation. This recommendation is based on the assumption of relevant local oxygen accumulation. The presented study aimed to characterise ambient oxygen concentrations during cardiopulmonary resuscitation (CPR) and to assess the effect of removing oxygen-delivery devices. Methods In a controlled mannequin-based simulation study, 20 resuscitation scenarios were performed under standardised conditions, varying oxygen delivery, airway management, ventilation mode, environment (room vs. ambulance), and distance of oxygen sources. Oxygen concentrations were continuously measured and recorded at 10-second intervals at three locations corresponding to typical defibrillation sites. Linear mixed-effects models were used to analyse predictors of oxygen fraction. Results A total of 6,555 oxygen measurements were recorded. Median oxygen concentration was 21.6% (IQR 21.3-22.1%). Removing oxygen delivery devices to > 1 m did not result in lower oxygen concentrations compared with leaving them in proximity of the mannequin's head. Endotracheal intubation compared to an open airway and the use of an OxyDemand valve compared to a reservoir with 15 L/min oxygen flow were associated with slightly lower oxygen fractions, whereas other factors (handling of upper garments, site, use of mechanical CPR) showed no clinically relevant effects. Conclusion Clinically relevant oxygen accumulation at defibrillation sites was not observed. Likewise, removing oxygen-delivery devices did not result in a reduction in oxygen concentrations. Under the tested conditions, these findings do not support clinically relevant oxygen enrichment during CPR, questioning the risk of oxygen-enriched atmospheres during CPR as well as the role of routine removal of oxygen sources prior to defibrillation.

More on this topic

Cardiac arrest and resuscitation

Subject terms

Manikins; Cardiopulmonary Resuscitation; Humans; Oxygen; Fires

DOI: 10.1186/s13049-026-01669-3 · PubMed: 42596016

Cite this article

Hoechter DJ, Pfeiffer F, Storz M, et al. Ambient oxygen enrichment during cardiopulmonary resuscitation: an overestimated risk? - Insights from a manikin study. Scand J Trauma Resusc Emerg Med. 2026. doi:10.1186/s13049-026-01669-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Randomized trial · Am J Emerg Med · Dec 7, 2024 · Emergency Medicine, Cardiology

Verbal motivation and metronome beats increased chest compression depth during dispatcher-assisted CPR simulations

Randomized trial · Am J Emerg Med · Jul 17, 2025 · Emergency Medicine, Critical Care

Mouth-to-mouth ventilation was faster to initiate than pocket masks or supraglottic airway devices on moving boats

Randomized trial · Resuscitation · Jan 30, 2021 · Critical Care, Cardiology

Personal protective equipment did not impair chest compression depth during out-of-hospital cardiopulmonary resuscitation

Randomized trial · Resuscitation · Oct 11, 2022 · Critical Care, Cardiology

Alcohol levels were not associated with cardiopulmonary resuscitation quality among festival attendees

Randomized trial · Scand J Trauma Resusc Emerg Med · Sep 4, 2021 · Emergency Medicine

Atypical rescuer positions during simulated avalanche rescue produced similar cardiopulmonary resuscitation quality to standard positions