Artificial Intelligence-Driven Angiographic Quantification of Fractional Flow Reserve: Proof-of-Concept Validation Study
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Angiography-based fractional flow reserve (FFR) techniques offer wire-free alternatives but often require manual segmentation and 3-dimensional reconstruction. Although an artificial intelligence-driven approach automates these steps, validation remains limited. This study investigated the diagnostic performance of an artificial intelligence-driven angiography-based FFR (medipixel FFR [MPFFR]), compared with quantitative flow ratio (QFR) in predicting functionally significant coronary artery stenosis defined by FFR ≤0.80. Methods
A total of 599 vessels from 452 patients who underwent clinically indicated FFR measurement were prospectively enrolled from 5 university hospitals in Korea. MPFFR used automated processes in frame selection, artificial intelligence contour detection, corresponding points matching, 3-dimensional reconstruction, and analytical hemodynamic modeling. The primary end point was diagnostic accuracy for detecting FFR ≤0.80. Secondary end points were target vessel failure (composite of cardiac death, target-vessel myocardial infarction, and target-vessel revascularization) at 2 years. Results
Mean analysis time of MPFFR was 12.5±1.7 seconds and manual correction was needed in 32 vessels (5.3%). MPFFR showed similar diagnostic performance with QFR (correlation with FFR; MPFFR versus QFR: R=0.885 versus R=0.860, P for comparison=0.011; area under the curve to predict FFR ≤0.80; 0.949 versus 0.953, P for comparison=0.631). At a median follow-up of 2 years (interquartile range, 1.6-2.6 years), patients with MPFFR ≤0.80 had higher risk of target vessel failure than those with MPFFR >0.80 (4.5% versus 0.8%; adjusted hazard ratio, 5.94 [95% CI, 1.27-27.91]; P=0.024). C-index to predict target vessel failure was comparable between MPFFR and QFR (0.770 versus 0.753, P for comparison=0.469). Conclusions
In this multicenter registry, an artificial intelligence-driven angiography-based FFR demonstrated comparable diagnostic accuracy with QFR in identifying functionally significant stenosis, and similar prognostic ability with QFR in terms of target vessel failure at 2 years. Registration
Multicenter QFR Registry; Unique Identifier: NCT03791788.
Topics
Spotted a mistake? Suggest a correction
More in Cardiology
Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations
Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis
Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately
Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms
Spontaneous coronary artery dissection affects younger women more often than expected
Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research
Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk
Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology