Visual abstractsVisuals
ResearchJACC: Advances · Mar 18, 2026

Artificial Intelligence-Driven Electrocardiogram Screening for Asymptomatic Left Ventricular Systolic Dysfunction in the General Population

Rhee TM, Kang S, Lee MS, Han GI, Yoo AH, Jang JH, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Asymptomatic left ventricular systolic dysfunction (LVSD) is a well-established precursor of overt heart failure (HF), yet it often remains undiagnosed in the general population. Artificial intelligence-enabled electrocardiogram (ECG) analysis offers a scalable approach for early detection. Objectives The purpose of this study was to evaluate the diagnostic performance of an artificial intelligence-enabled ECG model (AiTiALVSD) for identifying asymptomatic LVSD in a large health screening population. Methods In this retrospective, single-center study, we evaluated the AiTiALVSD model among 40,713 self-referred adults who underwent a total of 60,711 ECG-transthoracic echocardiography (TTE) pairs between 2011 and 2023. LVSD was defined as a left ventricular ejection fraction ≤40%. Model discrimination was assessed using the area under the receiver-operating characteristic curve (AUROC) and the area under the precision-recall curve (AUPRC), and diagnostic performance metrics were compared with established HF risk scores. Results Among 60,711 ECG-TTE pairs, 32 cases (0.054%) met the criteria for LVSD. The AiTiALVSD model demonstrated excellent discrimination (AUROC 0.973; AUPRC 0.328), with a sensitivity of 90.6%, specificity of 99.4%, positive predictive value of 7.7%, and a negative predictive value of 100%. Established HF risk scores, including the MESA (Multi-Ethnic Study of Atherosclerosis) 5-year HF score and Pooled Cohort Equations to Prevent HF score, showed inferior discrimination (AUROC: 0.696 and 0.672, respectively). The MESA score was not designed to detect prevalent LVSD and was calculated without natriuretic peptide data, which may have disadvantaged its performance in this comparison. Simulation analyses suggested that approximately 1,841 ECGs and 13 confirmatory TTEs would be required to detect one case of LVSD. Conclusions In a real-world screening population with an extremely low prevalence of LVSD, the AiTiALVSD model demonstrated high diagnostic accuracy, supporting its potential role as a rule-out screening tool for HF prevention. Prospective validation is warranted.

DOI: 10.1016/j.jacadv.2026.102660 · PubMed: 41849876

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology