Visual abstractsVisuals
ResearchJACC: Advances · Jan 20, 2026

Artificial Intelligence-Enhanced Electrocardiogram Models for Detection of Left Ventricular Dysfunction: A Comparison Study

Croon PM, Boonstra MJ, Allaart CP, Arends BKO, Dhingra LS, Huang YC, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Several artificial intelligence-enhanced electrocardiogram (AI-ECG) models have shown promise in detecting left ventricular systolic dysfunction (LVSD), but their head-to-head agreement and performance have not been independently compared within the same cohort. Objectives This study aimed to compare the performance of published AI-ECG models for LVSD detection in a standardized external cohort and evaluate the field's transparency and reproducibility. Methods We systematically reviewed AI-ECG models predicting LVSD and assessed the risk of bias. Authors were invited to share models for external validation in a well-phenotyped registry of patients undergoing routine clinical cardiac magnetic resonance imaging with cardiologist-adjudicated reports and paired ECGs. Model performance was evaluated in all consecutive patients and a lower-complexity subgroup with 15% LVSD prevalence. Results We identified 35 studies describing 51 models, reporting high (area under the receiver-operating characteristic curve [AUROC] >0.80) or excellent (AUROC >0.90) performance. The risk of bias is high and primarily attributed to the limited description of development and validation cohort characteristics, as well as the lack of independent external validation. Four groups (from Korea, the United States, Taiwan, and the Netherlands) shared models for independent testing. AUROCs ranged from 0.83 to 0.93 in all patients (n = 1,203; mean age 59 ± 15 years; 450 [35%] female) and from 0.87 to 0.96 in the lower-complexity subset. Performance remained consistent across subgroups, with slight decreases in ECGs showing wide QRS complexes or atrial fibrillation. Conclusions In this first-in-kind independent validation and head-to-head comparison study, AI-ECG for LVSD detection demonstrated strong performance despite training on disparate populations. However, the limited-availability of models hinders independent validation.

DOI: 10.1016/j.jacadv.2025.102572 · PubMed: 41564731

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology