Visual abstractsVisuals
ResearchAmerican Journal of Ophthalmology · Jan 2, 2026

Artificial Intelligence-Guided Endpoint Selection for Neuroprotection Trials in Glaucoma

R da Costa D, Scherer R, Swaminathan SS, Tseng H, A Medeiros F
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective Standard Automated Perimetry (SAP) is the primary method for monitoring glaucoma progression and an established functional endpoint in clinical trials. A ≥7 dB loss in at least five prespecified test locations has been proposed as a potential endpoint for glaucoma trials, but identifying such vulnerable points in advance remains a major challenge. We developed an artificial intelligence model that uses baseline SAP data to predict the locations most likely to progress, enabling a targeted approach to endpoint selection in neuroprotection trials. Design Retrospective cohort study to predict progression. Subjects A total of 82,449 SAP tests from 14,237 eyes of 10,533 subjects with open-angle glaucoma across three independent datasets: the Bascom Palmer Ophthalmic Registry, the Duke Glaucoma Registry, and the University of Washington Humphrey Visual Field. Methods A graph attention network was trained on Bascom Palmer Ophthalmic Registry data, split at the patient level into development and internal validation datasets, to predict progression risk at each SAP location using baseline total deviation values and anatomically informed graph connectivity. For each eye, the five highest-risk points (High-5) were identified and compared with global mean deviation (MD) and the five lowest-risk points (Low-5). The model was applied without retraining to the Duke Glaucoma Registry and University of Washington Humphrey Visual Field cohorts for external validation. Main outcome measures Model ranking performance, neighborhood hit rate, rates of change at High-5, Low-5, and MD, discrimination by area under the receiver operating characteristic curve, and time to repeatable ≥7 dB decline. Results In progressing eyes, mean slopes at High-5 were -2.05 to -2.32 dB/y, four to five times steeper than Low-5 (-0.45 to -0.66; P Conclusions The artificial intelligence-based model identified the most vulnerable visual field locations from baseline data. The High-5 metric provides a proof-of-concept framework consistent with regulatory concepts of functional endpoints and shows improved sensitivity to progression, supporting more efficient neuroprotection trials and personalized glaucoma monitoring.

Topics

Humans; Visual Fields; Retrospective Studies; Disease Progression; Artificial Intelligence; Glaucoma, Open-Angle; Visual Field Tests; Male; Female; Intraocular Pressure; Aged; Middle Aged

DOI: 10.1016/j.ajo.2025.12.038 · PubMed: 41485729

Spotted a mistake? Suggest a correction

More in Ophthalmology

ResearchPediatricAm J Ophthalmol · Nov 20, 2026 · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

Association of allergic conjunctivitis severity with meibomian gland abnormalities in children: a cross-sectional study

Randomized trialVisual abstractPediatricJAMA Ophthalmol · Nov 19, 2026 · Ophthalmology

Higher concentration atropine drops slowed myopia progression in children

Low-Concentration Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT2 Randomized Clinical Trial

ResearchAm J Ophthalmol · Nov 19, 2026 · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Smoke, Not Smoking, as a Possible Risk Factor Triggering Conversion in Leber's Hereditary Optic Neuropathy: A Retrospective Case Series

ResearchOphthalmology · Nov 18, 2026 · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Trends and Variation in Uveal Melanoma Management in the National Cancer Database, 2004-2023

ResearchAm J Ophthalmol · Nov 18, 2026 · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients

Developing Static Perimetry Thresholds to Assess Visual Field Loss Severity in Patients with Retinitis Pigmentosa