ResearchCritical Care · Jul 17, 2026
Assessing fluid responsiveness in mechanically ventilated patients with intra-abdominal hypertension: a two-center, prospective, observational study
Si X, Song W, Cao D, Zhu W, Lu Y, Peng H, et al
Abstract
Background
Intra-abdominal hypertension (IAH) may reduce the diagnostic accuracy of the passive leg raising (PLR) test for predicting fluid responsiveness, with unclear mechanisms. The reliability of the end-expiratory occlusion (EEO) test and mini-fluid challenge in IAH remains unknown. This study explored the mechanisms underlying PLR impairment and assessed the accuracy of EEO and mini-fluid challenge in detecting fluid responsiveness in patients with and without IAH. Methods
In this prospective study in two intensive care units (ICUs), we included ventilated patients with IAH ("IAH + "; intra-abdominal pressure [IAP] ≥ 12 mmHg) and without ("IAH-"), all monitored via transpulmonary thermodilution and receiving a 500-mL fluid challenge. Patients consecutively underwent a 1‑minute PLR, a 15‑second EEO, and a 1‑minute mini-fluid challenge of 100 mL, with cardiac index (CI) changes recorded during each maneuver. Following the mini-fluid challenge, the remaining 400 mL were infused over 14 min, and a ≥ 15% increase in CI was used to define fluid responders. The transmural pressure of the inferior vena cava was estimated by the central venous pressure (CVP) - IAP gradient. Results
We included 88 patients, 44 IAH- (25 fluid responders and 19 non-responders) and 44 IAH + (22 responders and 22 non-responders). Baseline IAP was 9 ± 2 mmHg in IAH- and 17 ± 3 mmHg in IAH + (p Conclusion
In patients with IAH, the limited diagnostic value of PLR for fluid responsiveness may be related to persistently negative CVP-IAP gradients in false-negative cases, whereas EEO and mini-fluid challenge remain reliable alternatives.
Topics
Humans; Prospective Studies; Fluid Therapy; Female; Intra-Abdominal Hypertension; Male; Respiration, Artificial; Middle Aged; Aged; Intensive Care Units; Thermodilution; Reproducibility of Results
DOI: 10.1186/s13054-026-06191-7 · PubMed: 42469838
Spotted a mistake? Suggest a correction
More in Critical Care
Meta-analysisCrit Care · Nov 19, 2026 · Critical Care
Discordant evidence on corticosteroids in sepsis: a meta-research study
ResearchPediatricResuscitation · Nov 17, 2026 · Critical Care
Survival after neonatal chest compressions at birth: Temporal trends and prognostic factors in a population-based cohort, Queensland, Australia
ResearchResuscitation · Nov 17, 2026 · Critical Care
Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones
ResearchResuscitation · Nov 17, 2026 · Critical Care
Out-of-hospital cardiac arrests due to foreign body airway obstruction: A CanROC registry, retrospective cohort study
ResearchResuscitation · Nov 17, 2026 · Critical Care