Assessing pulmonary function in 3-year-old children using respiratory oscillometry: a validation study in rural Guatemala
Grajeda LM, Castellanos K, Petrovick T, Díaz-Artiga A, López MR, Barraza-Villarreal A, et al
Abstract
Background
Respiratory oscillometry can inform early-life lung function, but evidence supporting its use in Guatemala is limited. We assessed the validity and reliability of respiratory oscillometry in 3-year-old Guatemalan children and whether these improve with quality control (QC). Methods
During home visits, we measured respiratory oscillometry resistance (R) and reactance (X) at 7 Hz (R7 and X7), the frequency dependence of resistance (R7-R19) and the area of reactance (AX) in 666 children participating in the Household Air Pollution Intervention Network trial. Standard measurement QC removed artefacts using commercial software and selected the first three measurements with an R7 coefficient of variation of ≤15%. Alternative investigators' methods varied in QC procedures. We evaluated validity as the proportion of variability in tests predicted by a child's height (R2) and, in a subset of 50 children, as agreement with test results after manual QC by a paediatric pulmonologist. Reliability was assessed by the intraclass correlation coefficient (ICC) of repeated tests. Results
We collected oscillometry results from 537 children. Height explained 5-15% of the variability in R7, X7 and AX, but none in R7-R19. The correlation between standard and manually cleaned tests ranged from 0.66 to 0.97, depending on the parameter. Of the first tests, between-day ICCs using the standard method for R7, R7-R19, X7 and AX were 0.68, 0.45, 0.60 and 0.71, respectively, and the best between-day ICCs using an alternative method were 0.75, 0.57, 0.69 and 0.74, respectively. Discussion
We demonstrated good validity and reliability of respiratory oscillometry measurements collected at home from preschool-aged Guatemalan children. Investigators' automated QC methodology performed equally to or better than standard methodology.
DOI: 10.1183/23120541.01238-2025 · PubMed: 42639403
Spotted a mistake? Suggest a correction
More in Pulmonology
ReviewEur Respir J · Nov 23, 2026 · Pulmonology
Solving an enigma: the BMP-9/10 axis as a key regulator of pulmonary vascular resilience
Needle aspiration versus intercostal chest drain for secondary spontaneous pneumothorax (the PRINCE-SSP trial): a pragmatic, open-label, multicentre, non-inferiority, randomised controlled trial
Safety and efficacy of inhaled itraconazole in adults with asthma and allergic bronchopulmonary aspergillosis (PUR1900-ABPA): a randomised, double-blind, parallel group, placebo-controlled, multicentre, phase 2 trial
ResearchChest · Nov 21, 2026 · Pulmonology
ResearchChest · Nov 21, 2026 · Pulmonology
Combination acetazolamide and supplemental oxygen markedly improves ventilatory control instability and OSA severity