Augmented Reality-Guided Decision Support in Simulated Pediatric Cardiac Arrest: A Randomized Clinical Trial
Abstract
Importance
Guideline-adherent management of pediatric in-hospital cardiac arrest (IHCA) remains challenging, and deviations from best practices are common. Augmented-reality (AR)-enabled, role-specific decision support may improve adherence to American Heart Association (AHA) Pediatric Advanced Life Support (PALS) guidance and key performance metrics. Objective
To determine whether an AR-enhanced, role-specific decision support system improves resuscitation performance and adherence to AHA PALS guidelines during simulated pediatric IHCA. Design, setting, and participants
This open-label, multicenter, simulation-based randomized clinical trial was conducted from April to May 2025 at 2 tertiary pediatric emergency centers (Geneva, Switzerland and Alberta, Canada). Participants included teams of pediatric nurses and physicians. Intervention
Teams managed a standardized scenario of a 12-minute IHCA due to hyperkalemia (progressing from nonshockable to shockable rhythms) using the AR-enhanced, role-specific decision support system (intervention) or AHA PALS pocket cards (control). Main outcomes and measures
The primary outcome was time from recognition of loss of pulse to first epinephrine. Secondary outcomes included adherence to 3- to 5-minute epinephrine dosing intervals, time to first defibrillation, adherence to 2-minute shock and rhythm-check cycles, chest compression fraction, peri-shock pause, medication-dosing accuracy, and user experience and technology acceptance. Results
A total of 54 participants were randomized into 18 teams (18 team leaders [12 female [71%] and 36 nurses [33 female [87%]), with 9 teams (27 participants) in each group. Mean (SD) time to first epinephrine was shorter in the intervention group (97.2 [38.5] vs 113.8 [44.5] seconds; mean difference, -16.6 seconds; 95% CI, -51.3 to 17.0 seconds; P = .40), but this difference was not significant. For subsequent epinephrine, the intervention group improved consistency: mean (SD) deviation from the 4-minute target was 17.2 (32.5) vs 49.7 (40.3) seconds (mean difference, -32.4 seconds; 95% CI, -58.8 to -5.8 seconds; P = .03), with fewer guideline violations (2 of 19 participants [11%] vs 9 of 21 participants [43%]; risk difference, -0.32; 95% CI, -0.55 to -0.05; risk ratio, 0.25; 95% CI, 0.06 to 0.996; P = .03). Time to first defibrillation and adherence to 2-minute cycles were similar between groups. Estimates for chest compression fraction, peri-shock pauses, and medication-dosing accuracy did not suggest meaningful between-group difference. User experience and technology acceptance were favorable. Conclusions and relevance
In this randomized clinical trial, AR support did not clearly improve time to first epinephrine in simulated pediatric cardiac arrest, with estimates compatible with both benefit and little or no effect. It improved adherence to epinephrine dosing intervals without impairing other performance domains. Trial registration
ClinicalTrials.gov Identifier: NCT06376643.
Topics
Spotted a mistake? Suggest a correction
More in Cardiology
Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations
Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis
Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately
Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms
Spontaneous coronary artery dissection affects younger women more often than expected
Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research
Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk
Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology