Visual abstractsVisuals
ResearchCritical Care · Mar 10, 2026

Augmenting the Simplified Acute Physiology Score II for intensive care unit mortality prediction and benchmarking: a French nationwide study

Kamel T, Boulain T
Critical CareAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

BACKGROUND: Severity scoring systems such as the Simplified Acute Physiology Score II (SAPS II) are widely used for benchmarking intensive care unit (ICU) performance, but their calibration deteriorates over time, leading to systematic overestimation of mortality in contemporary populations. We aimed to evaluate recalibrated SAPS II (r-SAPS II) and augmented SAPS II (Aug-SAPS II) models for mortality prediction using routinely collected national data. METHODS: This nationwide retrospective study used the French national database of hospital stays. Adult ICU stays from 2015 to 2023 constituted the derivation cohort; 2024 data were used for temporal external validation, and 2025 data for sensitivity analyses. Demographic characteristics, SAPS II score, and ICD-10–derived comorbidities defined according to the Elixhauser classification, were used to construct aug-SAPS II model. Model calibration was assessed using Cox calibration regression and standardized mortality ratios (SMRs), defined as the ratio of observed to predicted in-hospital deaths. Discrimination and between-hospital heterogeneity were quantified using the area under the receiver operating characteristic curve (AUC) and random-effects variance in SMRs from mixed-effects Poisson regression. RESULTS: In the derivation cohort (2 156 332 ICU stays), discrimination improved, with the AUC increasing from 0.841 (95% CI, 0.840–0.841) for SAPS II to 0.866 (95% CI, 0.865–0.866) for aug-SAPS II. Calibration improved for both r-SAPS II and aug-SAPS II, with calibration-in-the-large shifting from − 1.10 to approximately 0.00 and calibration slope from 0.72 to approximately 1.00 at both the hospital level and across clinical subgroups. In the validation cohort (242 465 stays), calibration remained close to ideal and SMRs were near 1; AUCs were 0.835 (95% CI, 0.833–0.837) for SAPS II and 0.862 (95% CI, 0.860–0.864) for aug-SAPS II. Hospital-level random-effects variance was unchanged with r-SAPS II but decreased by 28.7% with aug-SAPS II. Findings were consistent in 2025 data. CONCLUSIONS: Compared with the original SAPS II, aug-SAPS II improved calibration and discrimination and reduced between-hospital variability without requiring additional data beyond routinely collected national administrative information.

Topics

Humans; Intensive Care Units; Simplified Acute Physiology Score; France; Retrospective Studies; Female; Hospital Mortality; Male; Benchmarking; Aged; Middle Aged; ROC Curve

DOI: 10.1186/s13054-026-05948-4 · PubMed: 41808194

Spotted a mistake? Suggest a correction

More in Critical Care

Crit Care · Nov 19, 2026 · Meta-analysis · Critical Care

Corticosteroids in sepsis have conflicting mortality conclusions in reviews

Resuscitation · Nov 17, 2026 · Research · Pediatric · Critical Care

Eighty-nine percent of infants survived 28 days after chest compressions at birth in 2024

Resuscitation · Nov 17, 2026 · Research · Critical Care

Bystanders attaching AEDs had highest 30-day survival rate of 28 percent

Resuscitation · Nov 17, 2026 · Research · Critical Care

Foreign body airway obstruction caused 1.1% of out-of-hospital cardiac arrests

Resuscitation · Nov 17, 2026 · Research · Critical Care

Commercially available multimodal LLMs for EEG-based prognostication after cardiac arrest