Visual abstractsVisuals
ResearchOphthalmology Science · Aug 4, 2026

Automated Assessment of OCT Angiography Image Quality Using the Artificial Intelligence Ready and Exploratory Atlas for Diabetes Insights Data Set

Chen JS, Wedekind LE, Legala A, Tenerelli K, Most J, Ramesh N, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective OCT angiography (OCTA) images present challenges for clinical and research use due to variability and noise. The aim was to develop artificial intelligence models for OCTA image quality evaluation using the Artificial Intelligence Ready and Equitable Atlas for Diabetes Insights (AI-READI) data set. Design Cross-sectional study. Subjects Six thousand two hundred sixty-nine OCTA 6 × 6-mm and 325 12 × 12-mm macula-centered photographs of the superficial vascular plexus from 1067 AI-READI study participants, and 1100 6 × 6-mm OCTA photographs from 539 patients from the Massachusetts Eye and Ear Infirmary (MEEI). Methods All photographs were labeled as acceptable or poor quality by two ophthalmologists and five medical students. Predefined training and validation sets were used to fine-tune four deep learning (DL) models (ResNet, EfficientNet, Vision Transformer [ViT], and ConvNeXt v2) via hyperparameter grid search. Main outcome measures Model performance on all photographs from the AI-READI and MEEI test sets were assessed by accuracy, sensitivity, specificity, and area under the receiver operating characteristic (AUROC) scores. Results The accuracy/AUROC of the fine-tuned ResNet, EfficientNet, ViT, and ConvNeXt v2 models on the 6 × 6-mm AI-READI test set were 83.5%/0.904, 82.5%/0.904, 83.5%/0.908%, and 82.9%/0.913, with sensitivities/specificities of 77.9%/86.1%, 73.4%/89.9%, 69.2%/92.7%, and 79.8%/84.2%, respectively. The accuracy/AUROC of these models on the 6 × 6-mm MEEI test set were 91.5%/0.925, 94.3%/0.974, 93.9%/0.974%, and 88.0%/0.957, with sensitivities/specificities of 73.2%/98.4%, 84.5%/97.3%, 86.8%/97.2%, and 84.4%/92.7%, respectively. The accuracies/AUROC for the 12 × 12-mm photographs were 72.3%/0.775, 76.4%/0.775, 66.2%/0.979%, and 83.7%/0.834, with sensitivities/specificities of 95.7%/54.5%, 95.7%/57.8%, 97.9%/42.2%, and 96.4%/74.1%, respectively. Conclusions The AI-READI data set contains heterogeneous data usable for high-performing DL models for OCTA image quality assessment. These models were generalizable across institutions, cameras, and image sizes and may be used to rapidly screen OCTA image quality for use in future clinical studies. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101335 · PubMed: 42741389

Cite this article

Chen JS, Wedekind LE, Legala A, Tenerelli K, Most J, Ramesh N. Automated Assessment of OCT Angiography Image Quality Using the Artificial Intelligence Ready and Exploratory Atlas for Diabetes Insights Data Set. Ophthalmol Sci. 2026. doi:10.1016/j.xops.2026.101335

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine eye drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds developed to assess visual field loss severity in retinitis pigmentosa patients