Visual abstractsVisuals
ResearchThe Lancet Regional Health – Europe · Jul 24, 2026

Automated cardiac arrest detection using wrist-derived photoplethysmography during withdrawal of life-sustaining treatment: a prospective clinical validation study

Edgar R, Jansen CE, Pol LR, Ebrahimkheil K, van Kaam RC, Ronner E, et al
CardiologyCritical CareAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Automated cardiac arrest detection and alerting using wearable technology has the potential to shorten recognition delays for unwitnessed out-of-hospital cardiac arrest. In DETECT-1A and -1B, a photoplethysmography-based detection model was developed and validated in patients with induced cardiac arrest. This study evaluates model performance in true cardiac arrests following withdrawal of life-sustaining treatment. Methods Prospective, single-center study in adult ICU patients with planned withdrawal of life-sustaining treatment. Patients wore a photoplethysmography-wristband (CardioWatch) until death. Continuous ECG and invasive arterial pressure served as reference standards. The previously developed rule-based algorithm was refined using two training cohorts and evaluated in a separate test cohort. Endpoints were sensitivity for cardiac arrest detection and false positive alerts. Findings Forty-four patients were included (training 1: n = 10; training 2: n = 11; test: n = 23), median age 65 years; 75% male, all with non-shockable cardiac arrest. Sensitivity for cardiac arrest detection was 100% (10/10; 95% confidence interval [CI] 66-100%) and 90% (9/10; 95% CI 54-99%), in training 1 and 2, respectively. In the test set, sensitivity was 100% (23/23; 95% CI 82-100%), with one false positive alert. Cardiac arrest was detected at a mean arterial pressure of 30 mmHg (IQR 24-35) and pulse pressure of 13 mmHg (IQR 11-19). Interpretation Cardiac arrest can be detected with high sensitivity using wrist-derived photoplethysmography, providing first evidence on model performance in true cardiac arrest, specifically in non-shockable cases. Findings support further development of wearable-based cardiac arrest detection technologies to enable earlier recognition for unwitnessed cardiac arrest. Funding Dutch Heart Foundation, Radboudumc.

DOI: 10.1016/j.lanepe.2026.101791 · PubMed: 42542583

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology