Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence?

Kahrovic A, Herkner H, Werner P, Angleitner P, Coti I, Osipenko K, et al
Cardiothoracic & Vascular SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objectives This study aimed to assess long-term outcomes of automated titanium fasteners versus hand-tied knots in mitral valve surgery. Methods In this retrospective, single-centre analysis, 2678 adult patients who underwent mitral valve repair or replacement between November 2008 and November 2024 at the Medical University of Vienna were included. Patients were grouped according to the suture-securing technique used: automated titanium fasteners versus hand-tied knots. The primary endpoint was prosthetic dehiscence (either mitral annuloplasty ring or valve replacement prosthesis) requiring reintervention. Secondary endpoints comprised ischaemic stroke, intracranial bleeding, and all-cause mortality during the follow-up period. Results Among the study population, 1072 (40%) underwent mitral valve surgery using an automated titanium fastener device, and 1606 (60%) with conventional hand-tied sutures. A total of 31 patients (1.2%) had prosthetic dehiscence during the follow-up period. The risk of prosthetic dehiscence was significantly lower in the automated titanium fastener group in both univariable (crude sub-hazard ratio [sHR] 0.32; 95% confidence interval [CI], 0.12-0.86, P = .023) and multivariable competing risk regression analysis (adjusted sHR 0.34; 95% CI, 0.12-0.91, P = .033). Automated titanium fastener group was not associated with an increased risk of ischaemic stroke (adjusted sHR 0.92; 95% CI, 0.67-1.27, P = .600), intracranial bleeding (adjusted sHR 0.89; 95% CI, 0.52-1.52, P = .675), or all-cause mortality (adjusted hazard ratio 0.93; 95% CI, 0.74-1.18, P = .559). Conclusions The use of an automated titanium fastener device seems to be associated with a lower risk of prosthetic dehiscence in mitral valve surgery. Due to the limited number of prosthetic dehiscence events and the potential for residual confounding, the results should be interpreted with caution.

Topics

Humans; Retrospective Studies; Female; Mitral Valve; Male; Suture Techniques; Middle Aged; Heart Valve Prosthesis Implantation; Aged; Mitral Valve Annuloplasty; Heart Valve Prosthesis; Surgical Wound Dehiscence

DOI: 10.1093/ejcts/ezag013 · PubMed: 41512298

Spotted a mistake? Suggest a correction

More in Cardiothoracic & Vascular Surgery

Ann Thorac Surg · Nov 20, 2026 · Research · Pediatric · Cardiothoracic & Vascular Surgery

One-year survival improved in hybrid stage 1 single ventricle palliation over time

J Vasc Surg · Nov 16, 2026 · Research · Cardiothoracic & Vascular Surgery

Seven point five percent of patients developed vascular graft infection after bloodstream infection

J Vasc Surg · Nov 14, 2026 · Research · Cardiothoracic & Vascular Surgery

Fenestrated Endografts Provide Superior Outcomes Compared to Branched Devices in Juxtarenal Aortic Repair

Eur J Vasc Endovasc Surg · Nov 13, 2026 · Meta-analysis · Cardiothoracic & Vascular Surgery

Dual antiplatelet therapy showed no clear benefit after endovascular aortic repair

J Thorac Cardiovasc Surg · Nov 12, 2026 · Research · Cardiothoracic & Vascular Surgery

Early surgery did not increase hemorrhagic transformation in infective endocarditis patients