Abstract
Belz and colleagues present GREAT, a seven-item clinical instrument for predicting electroconvulsive therapy response in unipolar depression, with promising discriminatory validity (AUC 0.841). We identify three methodological gaps - absent calibration, limited sample representativeness and unquantified incremental value - that must be addressed before GREAT can guide individual clinical decisions.