Journal club handout · JAMA Ophthalmol · 2024-06-27

Capsular Tension Ring Implantation for Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Randomized Clinical Trial

Key result: Capsular tension rings reduce intraocular lens decentration and tilt in eyes with axial length 30 mm or longer

Randomized clinical trialBenefit found
Does capsular tension ring implantation reduce intraocular lens decentration and tilt in highly myopic eyes?
Who
186
Patients with cataract and axial length of 26 mm or longer · Zhongshan Ophthalmic Center, Guangzhou, China
Compared
Capsular tension ring group: 0.19 mm
Control group: 0.23 mm
Main outcome
Intraocular lens decentration at 3 months after cataract surgery
Result: difference, -0.04 mm; 95% CI, -0.07 to -0.01 mm
Bottom line: Capsular tension ring implantation reduced intraocular lens decentration and tilt in eyes with an axial length of 30 mm or longer.
JAMA Ophthalmol · 2024-06-27 · Save PNG

Key points

Why it matters: It is debated whether capsular tension rings are necessary for all highly myopic eyes to prevent intraocular lens decentration and tilt.

Discussion prompts

  1. Would these patients look like yours? Who was left out?
  2. Is the main outcome one that matters to patients?
  3. Is the difference large enough to change what you do?

Cite: Lin H, Zhang J, Zhang Y, et al. Capsular Tension Ring Implantation for Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Randomized Clinical Trial. JAMA Ophthalmol. 2024;142(8):708-715. doi:10.1001/jamaophthalmol.2024.2215