Cardiac output monitoring using an automatic arm cuff device in surgical patients

Jazini M, Daher H, Kumar R, Dhamotharan V, Sathe AM, Longhitano Y, et al
AnesthesiologyAdult
Read the full paper free at the publisher ↗

Abstract

Background Pulse contour devices estimate cardiac output (CO) from an invasive arterial blood pressure waveform. However, arterial catheters are generally used only in higher-risk patients. By contrast, automatic arm cuff devices are used for noninvasive BP monitoring in almost all hospital patients. Furthermore, these devices measure cuff pressure oscillations, which are directly related to pulsatile blood volume rather than BP. We hypothesised that automatic arm cuff devices can offer an effective means to monitor CO. Methods A custom-built cuff device was used to measure cuff pressure and make a unique measurement of the volume of air pumped into and out of the cuff during linear deflation. Cuff device measurements, an invasive BP waveform from a radial artery catheter, and reference CO from pulmonary artery catheter bolus thermodilution were obtained during interventions from 24 liver transplant and 10 cardiac surgery patients (191 measurement sets). A basic analysis was applied to estimate CO in L min-1 as the product of heart rate, the maximum cuff pressure oscillation amplitude, the cuff-arm system compliance (derived from the cuff pressure-volume relationship), and the body-to-arm surface area ratio (derived from anthropometric information). Results The arm cuff-based method yielded a correlation of 0.61 (95% confidence interval 0.37-0.79) and a concordance rate of 83% (75%-91%) against the reference CO. For comparison, classic pulse contour analysis of the invasive BP waveform produced a correlation of 0.59 (0.37-0.75) and a concordance rate of 81% (72%-90%). Conclusions These initial findings suggest potential for convenient CO monitoring using an automatic arm cuff device in surgical patients.

DOI: 10.1016/j.bja.2026.09.020 · PubMed: 42988714

Cite this article

Jazini M, Daher H, Kumar R, Dhamotharan V, Sathe AM, Longhitano Y. Cardiac output monitoring using an automatic arm cuff device in surgical patients. Br J Anaesth. 2026. doi:10.1016/j.bja.2026.09.020

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Anesthesiology

Br J Anaesth · Nov 20, 2026 · Research · Anesthesiology

Postoperative delirium accelerates brain ageing by six months

Br J Anaesth · Nov 20, 2026 · Research · Anesthesiology

Vaping-related disorder linked to higher postoperative respiratory complications risk

Br J Anaesth · Nov 20, 2026 · Research · Anesthesiology

Low perfusion index during surgery linked to higher 30-day mortality rates

Br J Anaesth · Nov 17, 2026 · Research · Anesthesiology

Ephedrine and phenylephrine increase human myometrial contractility ex vivo

BJA Open · Nov 13, 2026 · Meta-analysis · Pediatric · Anesthesiology

Effects of propofol- or sevoflurane-containing anaesthesia on auditory brainstem responses in children: a systematic review