CGM-derived average glucose is more strongly associated with microvascular complications than HbA1c in type 1 diabetes
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Aims
To compare the associations of HbA1c and continuous glucose monitoring (CGM)-derived average glucose with microvascular complications in adults with type 1 diabetes, and to assess the clinical utility and stability of metrics capturing glycation discordance. Materials and methods
Observational assessment of 9023 paired measurements of CGM data (14 days) and HbA1c in 2721 adults with type 1 diabetes. CGM metrics, HbA1c, and markers of discordance between HbA1c and CGM average glucose were associated with prevalent retinopathy (any and proliferative) and microalbuminuria. Results
HbA1c was higher than expected in older individuals (62 mmol/mol [54-71] age >45 vs. 61 mmol/mol [52-71], p = 0.004) and in women (62 mmol/mol [54-71] vs. 61 mmol/mol [53-71], p Conclusions
CGM-derived average glucose appears superior to HbA1c as a marker of prevalent microvascular complications. These data challenge the high-glycator hypothesis and also suggest glucose variability may be an independent risk marker for microvascular disease.