Coiled Polydioxanone Threads (JAMBER) for Nasal Augmentation: Efficacy, Longevity, and Safety
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Polydioxanone threads, specifically 40-mm tubular JAMBER (JB), 414-mm coiled around a 23G cannula, have emerged as a safe alternative for facial volume augmentation. This study evaluated the efficacy, safety, and longevity of JB threads for nasal augmentation, tracking changes in nasal height and volume across 12 months. Methods
A retrospective analysis included 23 patients (mean age 35.3 y; 8 men and 15 women) treated with JB threads from January 2023 to August 2024. Patients underwent ultrasound (Samsung RS85, Aplio i700, Konica Minolta HS2) and 3-dimensional scanner imaging (LifeViz Mini) at intervals of 1, 2, 3, 6, 9, and 12 months. An average of 2.85 JB threads were inserted in the nasal dorsum, complemented by 1.75 threads in the columella for tip projection. Results
The JB thread diameter decreased from 1.113 mm at 1 month to 0.857 mm at 12 months, reflecting gradual absorption. Soft-tissue thickness increased from 1.213 to 1.403 mm, indicating collagen formation. Nasal volume initially rose to 0.771 mL at 1 month and stabilized at 0.552 mL at 12 months. Similarly, nasal height increased to 1.387 mm at 1 month and remained at 1.005 mm by 12 months. No complications, such as infection or extrusion, were observed. Conclusions
JB threads provide effective and long-lasting nasal augmentation. Compared with fillers and implants, they offer a safer, minimally invasive alternative with no risk of vascular complications. Optimal outcomes require precise technique and patient selection. Further studies are warranted to validate these findings.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training