Visual abstractsVisuals
ResearchBJU International · May 11, 2026

Comparative 30-day life cycle assessment of bladder drainage strategies

Peyrottes A, Long-Depaquit T, Fourmarier M, Pradere B, Peyronnet B, Zieleskiewicz L, et al
UrologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective To identify the most environmentally sustainable urinary drainage strategies commonly used to manage bladder outlet obstruction and also to highlight actionable levers for reducing the footprint of urinary drainage in clinical practice. Materials and methods We conducted a comparative life cycle assessment of three urinary drainage strategies (i.e., indwelling urinary catheter, clean intermittent self-catheterisation [CISC], and temporary urethral stent) over a 30-day period, in accordance with International Organization for Standardization (ISO) 14040 and ISO 14044 standards. Primary data were collected via device disassembly and manufacturer consultation, with secondary data from the Ecoinvent version 3.9 database (Ecoinvent, Zurich, Switzerland). Impacts were modelled using the Environmental Footprint 3.0 method across 13 categories. Sensitivity analyses tested care delivery parameters and reusable catheters for CISC. Results The mean climate change impact over 30 days was 96.5 kg CO2 equivalents (CO2-eq; 95% confidence interval [CI] 58.8-162) for indwelling catheterisation, 39.8 kg CO2-eq (95% CI 31.2-53.3) for disposable CISC catheters, and 16.1 kg CO2-eq (95% CI 8.4-29.2) for the stent. Indwelling catheterisation consistently showed the highest impact, CISC intermediate, and the stent the lowest. Relative to catheterisation, the stent reduced climate impact by 83%, fossil resource use by 83%, and water consumption by 92%. Reusable CISC catheters showed a comparable profile to the stent. Sensitivity analyses confirmed that home nurse travel, device replacement frequency, and patient autonomy substantially influenced overall impact. Limitations include the mono-country design. Conclusions Device choice and care delivery models critically affect the environmental footprint of urinary drainage strategies. This study provides further strong arguments for promoting existing alternatives to the indwelling urinary catheter.

Topics

Humans; Stents; Urinary Bladder Neck Obstruction; Drainage; Catheters, Indwelling; Intermittent Urethral Catheterization; Urinary Catheterization; Urinary Catheters

DOI: 10.1111/bju.70304 · PubMed: 42109204

Cite this article

Peyrottes A, Long-Depaquit T, Fourmarier M, Pradere B, Peyronnet B, Zieleskiewicz L. Comparative 30-day life cycle assessment of bladder drainage strategies. BJU Int. 2026. doi:10.1111/bju.70304

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

BJU Int · Jul 27, 2026 · Randomized trial · Pediatric · Urology Visual abstract

Stent and saline irrigation reduced complication rates after hypospadias repair in adolescents

JAMA Netw Open · Jun 1, 2026 · Randomized trial · Urology Visual abstract

Reusable catheters were as safe as single-use catheters for preventing urinary tract infections

BMJ Open Respir Res · Mar 19, 2026 · Research · Pulmonology

Management of malignant pleural effusions using an indwelling tunnelled pleural catheter and non-vacuum collection system

BJU Int · May 31, 2026 · Research · Pediatric · Urology

Lateral drainage metal ureteric stent for the treatment of 'Y-shaped' branch obstructive uropathy

Br J Gen Pract · Oct 1, 2026 · Research · Family Medicine & Primary Care

Diagnostic models for male lower urinary tract symptom management in primary care: a prospective, multicentre, diagnostic accuracy study