ResearchJournal of Vascular Surgery · May 19, 2026

Comparative analysis of bridging stent outcomes in fenestrated and branched endovascular aortic aneurysm repair

Mahmood DN, Elzawy G, Haqani B, Lindsay TF, Tan K, Mafeld S, et al
Cardiothoracic & Vascular SurgeryCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Objective This study aimed to evaluate associations between bridging stent graft (BSG) type, anatomic location, and midterm primary patency across different BSGs used for fenestrated/branched endovascular aortic aneurysm repair (F/BEVAR). Methods We retrospectively reviewed 321 patients who underwent elective and urgent F/BEVAR between November 2007 and December 2022 at a single academic institution. All repairs involved custom or off-the-shelf devices targeting the renal and mesenteric arteries using BSGs selected at the operator's discretion. BSGs included Atrium Advanta V12, Gore Viabahn, Gore Viabahn VBX Balloon Expandable Endoprosthesis, Bard LifeStream, and Bentley BeGraft Peripheral. The primary outcome was BSG primary patency at 5 years. Secondary end points included primary-assisted and secondary patency, overall target-vessel instability, and assessment of factors associated with primary patency loss. Results Among the 321 patients (76.9% male, median age 76 years), 1171 BSGs were deployed. Overall technical success was 89.7%, with in-hospital mortality of 5.6%. At 5 years, estimated primary, primary-assisted, and secondary patency rates were 80.5%, 85.8%, and 90.0%, respectively, with 68.7% freedom from target-vessel instability (log-rank P < .001). Primary patency by BSG type was: Advanta V12 94.6%, Viabahn 93.9%, VBX 91.6%, LifeStream 76.7% at 5 years, and 95.1% for BeGraft Peripheral at 2 years (P < .0001). On multivariable analysis, use of LifeStream stents was independently associated with higher odds of primary patency loss (odds ratio [OR]: 3.83, 95% confidence interval [CI]: 2.05-7.04, P < .001), and both left (OR: 2.39, 95% CI: 1.19-5.13) and right (OR: 2.26, 95% CI: 1.10-4.94) renal artery targets demonstrated lower primary patency compared with mesenteric vessels. No significant differences in primary patency rates were observed between fenestrations and branches. Conclusions In this single-center series of over 1100 BSGs with up to 15 years of follow-up, BSG type and anatomic location were associated with reduced primary patency. LifeStream stents and renal arteries were associated with loss of primary patency, whereas BeGraft Peripheral showed promising early outcomes. These findings support the need for continued surveillance after F/BEVAR and highlight the need for further research to define optimal stent selection strategies.

Subject terms

Humans; Retrospective Studies; Endovascular Aneurysm Repair; Stents; Vascular Patency; Blood Vessel Prosthesis; Prosthesis Design; Time Factors; Male; Aged; Female; Risk Factors

DOI: 10.1016/j.jvs.2026.05.017 · PubMed: 42162623

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Mahmood DN, Elzawy G, Haqani B, et al. Comparative analysis of bridging stent outcomes in fenestrated and branched endovascular aortic aneurysm repair. J Vasc Surg. 2026;84(4):789-801.e2. doi:10.1016/j.jvs.2026.05.017

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiothoracic & Vascular Surgery studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · Ann Thorac Surg · Jun 13, 2026 · Cardiothoracic & Vascular Surgery, Cardiology

A Novel Single-Branched Stent-Graft System for Aortic Dissection Involving the Aortic Arch

Research · J Vasc Surg · Jun 2, 2026 · Cardiothoracic & Vascular Surgery, Physical Medicine & Rehabilitation

Anatomic feasibility of off-the-shelf fenestrated endovascular aneurysm repair devices: An anatomic study

Meta-analysis · Eur J Vasc Endovasc Surg · Mar 27, 2026 · Cardiothoracic & Vascular Surgery, Cardiology

Custom made and off the shelf endografts show high technical success rate for LSA preservation

Meta-analysis n = 3,890 · Eur J Vasc Endovasc Surg · Jan 13, 2025 · Cardiothoracic & Vascular Surgery, Physical Medicine & Rehabilitation

Advanta V12 or iCAST bridging stents show high rates of stability in aortic repairs

Systematic review · Eur J Vasc Endovasc Surg · May 26, 2025 · Cardiothoracic & Vascular Surgery, Infectious Disease

Omniflow II biosynthetic grafts show high freedom from re-infection in infrainguinal vascular reconstruction