Comparative Performance of Common Fecal Immunochemical Tests : A Cross-Sectional Study
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Despite widespread use of fecal immunochemical tests (FITs) for colorectal cancer (CRC) screening, data to guide test selection are limited. Objective
To compare the performance characteristics of 5 commonly used FITs, using colonoscopy as the reference standard. Design
Cross-sectional study. (ClinicalTrials.gov: NCT03264898). Setting
Three U.S. academic medical centers and affiliated endoscopy units. Participants
Patients aged 50 to 85 years undergoing screening or surveillance colonoscopy. Intervention
Participants completed 5 different FITs before their colonoscopy, including 4 qualitative tests (Hemoccult ICT, Hemosure iFOB, OC-Light S FIT, QuickVue iFOB) and 1 quantitative test (OC-Auto FIT, which was run at the manufacturer's threshold for positivity of >100 ng/mL). Measurements
The primary outcome was test performance (sensitivity and specificity) for each of the 5 FITs for advanced colorectal neoplasia (ACN), defined as advanced polyps or CRC. Positivity rates, positive and negative predictive values, and rates of unevaluable tests were compared. Multivariable models were used to identify factors affecting sensitivity. Results
A total of 3761 participants were enrolled, with a mean age of 62.1 years (SD, 7.8); 63.2% of participants were female, 5.7% were Black, 86.4% were White, and 28.7% were Hispanic. There were 320 participants with ACN (8.5%), including 9 with CRC (0.2%). The test positivity rate varied 4-fold (3.9% to 16.4%) across FITs. Rates of unevaluable FITs ranged from 0.2% to 2.5%. The sensitivity for ACN varied from 10.1% to 36.7%, and specificity varied from 85.5% to 96.6%. Differences in sensitivity between FITs were all statistically significantly different except between Hemosure iFOB and QuickVue iFOB, and specificity differences were all statistically significantly different from one another. In addition to FIT brand, distal location of ACN was also associated with higher FIT sensitivity. Limitation
The study did not assess the programmatic sensitivity of annual FIT. Conclusion
Although considered a single class, FITs have varying test performance for detecting ACN and should not be considered interchangeable. Primary funding source
National Institutes of Health.
Topics
Cite this article
Levy BT, Xu Y, Daly JM, Hoffman RM, Dawson JD, Shokar NK. Comparative Performance of Common Fecal Immunochemical Tests : A Cross-Sectional Study. Ann Intern Med. 2024. doi:10.7326/M24-0080
Spotted a mistake? Suggest a correction