QuantiFERON-TB Gold Plus shows similar diagnostic performance to QuantiFERON-TB Gold In-Tube tests
Comparing the Diagnostic Performance of QuantiFERON-TB Gold Plus to Other Tests of Latent Tuberculosis Infection: A Systematic Review and Meta-analysis
Clinical question: How does QuantiFERON-TB Gold Plus compare to other latent tuberculosis infection tests?
Why it matters: It was unknown if the QuantiFERON-TB Gold Plus test offers diagnostic advantages over the QuantiFERON-TB Gold In-Tube test.
- Researchers performed a systematic review and meta-analysis of studies comparing QuantiFERON-TB Gold Plus to other latent tuberculosis infection tests.
- The sensitivity of QuantiFERON-TB Gold Plus was 1.3% higher in patients with active tuberculosis, but this difference was not statistically significant.
- The specificity was 0.9% lower in two studies of people with a very low probability of infection, which was also not statistically significant.
Limitation the authors note: The authors noted a lack of studies assessing predictive ability and a need for more research in younger children and immunocompromised patients.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Oh CE, Ortiz-Brizuela E, Bastos ML, Menzies D. Comparing the Diagnostic Performance of QuantiFERON-TB Gold Plus to Other Tests of Latent Tuberculosis Infection: A Systematic Review and Meta-analysis. Clin Infect Dis. 2020. doi:10.1093/cid/ciaa1822
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.
Get the weekly digest