ResearchAnnals of Internal Medicine · Oct 11, 2022

Comparison of Rapid Antigen Tests' Performance Between Delta and Omicron Variants of SARS-CoV-2 : A Secondary Analysis From a Serial Home Self-testing Study

Soni A, Herbert C, Filippaios A, Broach J, Colubri A, Fahey N, et al
Infectious DiseaseAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background It is important to document the performance of rapid antigen tests (Ag-RDTs) in detecting SARS-CoV-2 variants. Objective To compare the performance of Ag-RDTs in detecting the Delta (B.1.617.2) and Omicron (B.1.1.529) variants of SARS-CoV-2. Design Secondary analysis of a prospective cohort study that enrolled participants between 18 October 2021 and 24 January 2022. Participants did Ag-RDTs and collected samples for reverse transcriptase polymerase chain reaction (RT-PCR) testing every 48 hours for 15 days. Setting The parent study enrolled participants throughout the mainland United States through a digital platform. All participants self-collected anterior nasal swabs for rapid antigen testing and RT-PCR testing. All Ag-RDTs were completed at home, whereas nasal swabs for RT-PCR were shipped to a central laboratory. Participants Of 7349 participants enrolled in the parent study, 5779 asymptomatic persons who tested negative for SARS-CoV-2 on day 1 of the study were eligible for this substudy. Measurements Sensitivity of Ag-RDTs on the same day as the first positive (index) RT-PCR result and 48 hours after the first positive RT-PCR result. Results A total of 207 participants were positive on RT-PCR (58 Delta, 149 Omicron). Differences in sensitivity between variants were not statistically significant (same day: Delta, 15.5% [95% CI, 6.2% to 24.8%] vs. Omicron, 22.1% [CI, 15.5% to 28.8%]; at 48 hours: Delta, 44.8% [CI, 32.0% to 57.6%] vs. Omicron, 49.7% [CI, 41.6% to 57.6%]). Among 109 participants who had RT-PCR-positive results for 48 hours, rapid antigen sensitivity did not differ significantly between Delta- and Omicron-infected participants (48-hour sensitivity: Delta, 81.5% [CI, 66.8% to 96.1%] vs. Omicron, 78.0% [CI, 69.1% to 87.0%]). Only 7.2% of the 69 participants with RT-PCR-positive results for shorter than 48 hours tested positive by Ag-RDT within 1 week; those with Delta infections remained consistently negative on Ag-RDTs. Limitation A testing frequency of 48 hours does not allow a finer temporal resolution of the analysis of test performance, and the results of Ag-RDTs are based on self-report. Conclusion The performance of Ag-RDTs in persons infected with the SARS-CoV-2 Omicron variant is not inferior to that in persons with Delta infections. Serial testing improved the sensitivity of Ag-RDTs for both variants. The performance of rapid antigen testing varies on the basis of duration of RT-PCR positivity. Primary funding source National Heart, Lung, and Blood Institute of the National Institutes of Health.

More on this topic

COVID-19

Subject terms

United States; Humans; SARS-CoV-2; COVID-19; Prospective Studies; Self-Testing; Sensitivity and Specificity

DOI: 10.7326/M22-0760 · PubMed: 36215709

Cite this article

Soni A, Herbert C, Filippaios A, Broach J, Colubri A, Fahey N. Comparison of Rapid Antigen Tests' Performance Between Delta and Omicron Variants of SARS-CoV-2 : A Secondary Analysis From a Serial Home Self-testing Study. Ann Intern Med. 2022. doi:10.7326/M22-0760

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Randomized trial · JAMA Netw Open · Jun 2, 2025 · Infectious Disease

Distributing COVID-19 self-test kits to social contacts did not increase testing rates

Meta-analysis · Emerg Infect Dis · Feb 24, 2021 · Infectious Disease

Pooling sputum samples for tuberculosis testing may maintain high accuracy while saving cartridges

Meta-analysis · Euro Surveill · May 25, 2023 · Infectious Disease

SARS-CoV-2 antibody test sensitivity decreases over time depending on the specific assay used

Meta-analysis · Diagn Pathol · Apr 13, 2022 · Pathology & Laboratory Medicine, Infectious Disease

Sample type and viral load influence the sensitivity of rapid diagnostic tests for COVID-19

Meta-analysis · Ann Intern Med · Jan 12, 2021 · Infectious Disease

Saliva sampling was nearly as sensitive as nasopharyngeal swabs for SARS-CoV-2 detection