Meta-analysisJournal of the American Heart Association · Sep 9, 2024

Computed Tomography Imaging Measurements as a Surrogate for Clinical Outcomes After Surgical Management of Acute Type A Aortic Dissection: A Systematic Review

Vo TX, Rahmouni K, Visintini S, Guo MH, Ouzounian M, Chu MWA, et al
CardiologyRadiology & ImagingAdult
Systematic reviewMixed results
Are computed tomography measurements effective surrogates for clinical outcomes after acute type A aortic dissection repair?
Who
7885
Patients after acute type A aortic dissection repair
Compared
Extended repairs: improved false lumen thrombosis, decreased aortic growth rate, and decreased rates of reintervention
Standard repairs: not improved survival
Main outcome
Mortality or aortic reintervention after 1 year
Bottom line: Extended repairs improve false lumen thrombosis and growth rates but do not improve survival.
Limitation: Future studies should prospectively evaluate and compare prognostic factors.
J Am Heart Assoc · 2024-09-09Download image

Clinical question: Are computed tomography measurements effective surrogates for clinical outcomes after acute type A aortic dissection repair?

Read the full paper free at PubMed Central ↗

Abstract

Background Postoperative computed tomography imaging surveillance is an essential component of care after acute type A aortic dissection (ATAAD) repair. Prognostic imaging factors after ATAAD repair have not been systematically reviewed. Methods and results We performed a systematic review to summarize postoperative computed tomography measurements including aortic diameter, cross-sectional area, volume, growth rate, and false lumen thrombosis in addition mid- to long-term clinical outcomes after ATAAD repair. Searches were conducted in Medline, Embase, and CENTRAL in October 2022. Studies were included if they reported clinical outcomes such as mortality or aortic reintervention after 1 year and included aforementioned computed tomography findings. Studies of chronic aortic dissection and studies of exclusive patient populations such as those with connective tissue diseases were excluded. Risk of bias was assessed with the Newcastle-Ottawa Scale. Searches retrieved 6999 articles. Sixty-eight studies met inclusion criteria (7885 patients). Extended repairs were associated with improved false lumen thrombosis, decreased aortic growth rate, and decreased rates of reintervention but not improved survival. Growth rates of the aorta post-ATAAD repair were highest in the descending thoracic aorta. The most frequent prognostic imaging factors reported were a patent/partially thrombosed false lumen and postoperative aortic diameter >40 to 45 mm. Conclusions Established measurements of positive aortic remodeling, including complete false lumen thrombosis and stabilization of postoperative aortic diameter and growth are the most studied prognostic indicators for improved clinical outcomes after ATAAD repair. Growth rate of the aorta remains significant after ATAAD repair. Future studies should prospectively evaluate and compare prognostic factors for improved surveillance and management.

Topics

Humans; Aortic Dissection; Acute Disease; Treatment Outcome; Aortic Aneurysm, Thoracic; Tomography, X-Ray Computed; Computed Tomography Angiography; Prognosis; Aorta, Thoracic; Blood Vessel Prosthesis Implantation; Aortic Aneurysm

DOI: 10.1161/JAHA.124.034496 · PubMed: 39248260

Cite this article

Vo TX, Rahmouni K, Visintini S, Guo MH, Ouzounian M, Chu MWA. Computed Tomography Imaging Measurements as a Surrogate for Clinical Outcomes After Surgical Management of Acute Type A Aortic Dissection: A Systematic Review. J Am Heart Assoc. 2024. doi:10.1161/JAHA.124.034496

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Meta-analysis · Eur J Cardiothorac Surg · Nov 1, 2024 · Cardiothoracic & Vascular Surgery, Cardiology

Aortic arch replacement in patients with previous aortic dissection repair shows 8.7% early mortality

Meta-analysis · Int J Surg · Jul 24, 2025 · Surgery, Cardiology

Stent graft misplacement in the false lumen of aortic dissections was linked to high mortality

Research · Eur J Cardiothorac Surg · Dec 18, 2025 · Cardiothoracic & Vascular Surgery, Cardiology

Concomitant Aortic Root Replacement in Total Arch Replacement With Frozen Elephant Trunk for Type A Aortic Dissection: A Propensity-Weighted Analysis

Clinical trial · J Am Heart Assoc · Dec 10, 2025 · Cardiology, Cardiothoracic & Vascular Surgery

Left Subclavian Artery Revascularization With In Situ Laser Fenestration During Thoracic Endovascular Aortic Repair for Acute Complicated or High-Risk Type B Aortic Dissection: Results of the LLTEVAR Trial

Research · Br J Surg · Feb 17, 2026 · Surgery, Cardiology

Open surgery versus branched endovascular repair of the aortic arch in residual dissections after type A surgical repair