Visual abstractsVisuals
ResearchIntensive Care Medicine · Feb 13, 2026

Consensus on identifying and ranking ventilator asynchronies in invasively ventilated ICU patients: a modified Delphi study (SYNAPsE)

Molenaar MA, Nasa P, Damiani LF, Ferreira JC, Isola A, Paulus F, et al
Critical CareAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose Despite extensive research, it remains unclear which patient-ventilator asynchronies are reliably detectable in clinical practice, most clinically relevant, and how they rank in severity. Methods Multiple-choice questions and 5-point Likert-scale statements were used in iterative Delphi rounds. Feedback was incorporated until stable consensus or dissensus was reached for all items. First series of rounds focused on identifying and classifying patient-ventilator asynchronies detectable from ventilator waveforms, second series assessed their associations with outcomes in three patient groups, and in the final rounds, asynchronies were ranked by severity within these patient groups and across three scenarios. Results In total, 11 panelists completed nine rounds. Consensus classified ineffective triggering, reverse triggering, double triggering, auto-triggering, insufficient flow, premature cycling, and delayed cycling as clinically relevant patient-ventilator asynchronies. Of these, auto-triggering and delayed cycling were deemed unlikely to be detectable using ventilator waveforms alone. Across all three patient groups, the panelists reached consensus that double triggering and ineffective triggering were the most clinically relevant. In acute respiratory distress syndrome, double triggering, ineffective triggering, and reverse triggering were all judged clinically relevant. In patients without acute respiratory distress syndrome and after cardiac surgery, asynchronies were classified as severe or mild and combined into two composite groups. Conclusion This Delphi study provides a consensus-based framework for identifying and ranking patient-ventilator asynchronies at the bedside, highlighting those most likely to be clinically relevant and offering a structured approach to support monitoring, intervention, and future research.

Topics

Humans; Delphi Technique; Patient-Ventilator Asynchrony; Intensive Care Units; Respiration, Artificial

DOI: 10.1007/s00134-026-08328-2 · PubMed: 41686209

Spotted a mistake? Suggest a correction

More in Critical Care

Meta-analysisCrit Care · Nov 19, 2026 · Critical Care

Corticosteroids in sepsis have conflicting mortality conclusions in reviews

Discordant evidence on corticosteroids in sepsis: a meta-research study

ResearchPediatricResuscitation · Nov 17, 2026 · Critical Care

Eighty-nine percent of infants survived 28 days after chest compressions at birth in 2024

Survival after neonatal chest compressions at birth: Temporal trends and prognostic factors in a population-based cohort, Queensland, Australia

ResearchResuscitation · Nov 17, 2026 · Critical Care

Bystanders attaching AEDs had highest 30-day survival rate of 28 percent

Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones

ResearchResuscitation · Nov 17, 2026 · Critical Care

Foreign body airway obstruction caused 1.1% of out-of-hospital cardiac arrests

Out-of-hospital cardiac arrests due to foreign body airway obstruction: A CanROC registry, retrospective cohort study

ResearchResuscitation · Nov 17, 2026 · Critical Care

Commercially available multimodal LLMs for EEG-based prognostication after cardiac arrest