Meta-analysisAnnals of Intensive Care · May 12, 2026
Correlation between central venous oxygen saturation and mixed venous oxygen saturation in surgical patients: A systematic review and meta-analysis
Li L, He LX, Yao YT, Evidence in Cardiovascular Anesthesia (EICA) Group
Abstract
Background
The validity of central venous oxygen saturation (ScvO2) as a surrogate for mixed venous oxygen saturation (SvO₂) in surgical patients remains uncertain. Methods
We systematically searched PubMed, Embase, the Cochrane Library, China National Knowledge Infrastructure (CNKI), Wanfang, VIP, and the Chinese BioMedical Literature & Retrieval System (SinoMed) up to March 31st 2026 for observational studies reporting paired perioperative ScvO2 and SvO2 measurements in surgical patients. Two reviewers independently screened studies, extracted data, and assessed quality using the Newcastle-Ottawa Scale (NOS). The primary outcome was clinical interchangeability, pre-defined as both the pooled mean difference (MD) 95% confidence interval (CI) and 95% limits of agreement (LOA) within ±5%. Correlation was a secondary outcome via Fisher's z transformation. For studies reporting multiple measurements within a single perioperative phase, arithmetic means were used to avoid unit-of-analysis errors. Random-effects models were prespecified for all pooled analyses, supplemented by pre-planned subgroup and sensitivity analyses to explore heterogeneity. Results
Twenty-eight studies including 1369 patients were analyzed. In studies reporting aggregated perioperative data (10 studies, n = 524), ScvO2 and SvO₂ were not clinically interchangeable: pooled MD was -0.49% (95% CI, -1.34 to 0.35; I² = 70.3%), and LOA (-12.15% to 11.17%) exceeded the predefined ±5% threshold for clinical acceptability, consistent with observations across perioperative phases. The pooled correlation was 0.72 (5 studies, n = 197; 95% CI 0.57-0.82; I² = 64.3%). Subgroup analyses showed narrower LOA and higher correlation in non-cardiovascular and off-pump procedures. Conclusions
ScvO2 is positively correlated with SvO₂ in the perioperative period. However, wide individual-level LOA indicate that the two measurements are not interchangeable in surgical patients. LOA are narrower in non-cardiovascular and off-pump procedures but remain outside clinically acceptable limits.
DOI: 10.1016/j.aicoj.2026.100076 · PubMed: 42179656
Spotted a mistake? Suggest a correction
More in Critical Care
Meta-analysisCrit Care · Nov 19, 2026 · Critical Care
Discordant evidence on corticosteroids in sepsis: a meta-research study
ResearchPediatricResuscitation · Nov 17, 2026 · Critical Care
Survival after neonatal chest compressions at birth: Temporal trends and prognostic factors in a population-based cohort, Queensland, Australia
ResearchResuscitation · Nov 17, 2026 · Critical Care
Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones
ResearchResuscitation · Nov 17, 2026 · Critical Care
Out-of-hospital cardiac arrests due to foreign body airway obstruction: A CanROC registry, retrospective cohort study
ResearchResuscitation · Nov 17, 2026 · Critical Care