Randomized trialBritish Journal of Anaesthesia · Dec 16, 2021

Cuffed versus uncuffed tracheal tubes in a rabbit training model for establishing an emergency front-of-neck airway in infants: a prospective trial

Thomas J, Alonso E, Wendel Garcia PD, Diem B, Kemper M, Weiss M, et al
AnesthesiologyPulmonologyPediatricsPediatric
Read the full paper free at the publisher ↗

Abstract

Background There is a paucity of evidence regarding the optimal type of tracheal tube to be advanced over a Frova catheter when performing a 'bougie' emergency front-of-neck airway (eFONA) technique in infants during a 'cannot intubate, cannot oxygenate' situation. Methods A prospective non-inferiority trial in a rabbit cadaver surgical tracheotomy model to assess the performance of the eFONA technique with an uncuffed 3.5 mm ID tracheal tube vs a cuffed 3.0 mm ID tracheal tube. Queried outcomes include success rate, performance time, and severe secondary airway injuries among tracheal tube types. Results In 60 tracheostomies performed by 30 participants, the overall success rate was 98%. Performance time was independent from tracheal tube choice (uncuffed: 61 s [95% confidence interval (CI), 52-76], cuffed: 64 s [95% CI, 55-79]; P = 0.82). No tracheal tube type was preferred in terms of usability by participants. The cuffed tracheal tube required increased force to be advanced over the Frova catheter and was associated with a risk ratio of 2.5 (95% CI, 0.53-11.9; number needed to harm, 10) for severe secondary airway injuries when compared with the uncuffed tracheal tube. Conclusion In performing eFONA in the rabbit cadaver model, an ID 3.5 uncuffed is non-inferior to an ID 3.0 cuffed tracheal tube regarding performance time and preference by the operator. Greater force application to advance the cuffed tube over the Frova catheter and more severe airway injuries may argue for the standardised performance of the eFONA technique with a uncuffed tracheal tube in infants.

Topics

Animals; Cross-Over Studies; Equipment Design; Humans; Infant; Intubation, Intratracheal; Models, Animal; Prospective Studies; Rabbits; Respiratory System; Tracheotomy

DOI: 10.1016/j.bja.2021.11.017 · PubMed: 34920855

Cite this article

Thomas J, Alonso E, Wendel Garcia PD, Diem B, Kemper M, Weiss M. Cuffed versus uncuffed tracheal tubes in a rabbit training model for establishing an emergency front-of-neck airway in infants: a prospective trial. Br J Anaesth. 2021. doi:10.1016/j.bja.2021.11.017

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Meta-analysis · Anesth Analg · Dec 17, 2021 · Anesthesiology, Pulmonology

Airway Ultrasound as Predictor of Difficult Direct Laryngoscopy: A Systematic Review and Meta-analysis

Meta-analysis · Br J Anaesth · Oct 15, 2024 · Anesthesiology, Pulmonology

Network meta-analysis ranks different supraglottic airway devices for various clinical outcomes

Randomized trial · Br J Anaesth · Aug 20, 2022 · Pediatric · Anesthesiology, Pediatrics

Comparison of two sizes of GlideScope® blades in tracheal intubation of infants: a randomised clinicaltrial

Meta-analysis · Br J Anaesth · Jul 22, 2021 · Anesthesiology, Pulmonology

Airway devices for awake tracheal intubation in adults: a systematic review and network meta-analysis

Randomized trial · Anaesthesia · Nov 27, 2024 · Anesthesiology, Critical Care

Clinicians reached proficiency in hyperangulated videolaryngoscopy after a median of 12 intubation attempts