Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Apr 15, 2026

Customizing native T1 mapping: The effects of compressed sensing, deep learning-based denoising, and high-resolution on measurement of native myocardial T1

Perazzolo A, Vita CV, Scialò V, Gamal M, Bruno E, Chao TC, et al
Radiology & ImagingDigital Health & AICardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Quantitative native T1 mapping is a key component in cardiovascular magnetic resonance (CMR) for myocardial tissue characterization; however, further improvements in acquisition efficiency and robustness are needed to optimize clinical applicability. Undersampling techniques in k-space, such as compressed sensing (CS) and deep learning-based (DL) denoising reconstructions, have improved morphological and cine-imaging, but their impact on quantitative relaxation times remains underexplored. This study evaluated image quality and native T1 quantification across ten combinations with varying CS acceleration levels, spatial resolutions, and application of DL-denoising reconstruction. Methods In this prospective single-center study, 48 healthy volunteers underwent native T1 mapping. After quality review, 41 subjects were included. Blurring, aliasing, susceptibility artifacts, and overall image quality (IQ) were rated by three blinded readers using a 4-point Likert scale. Quantitative analysis was performed on a per-segment basis using custom software, yielding mean native T1 values for each AHA segment. Nine cases were reanalyzed by three additional readers to assess interobserver variability. Test-retest and phantom experiments were performed to assess reproducibility and to cover pathological T1 ranges, respectively. The reference T1-mapping protocol was obtained with CS3, with spatial resolution of 2.0×2.0×10mm3. Additional acquisitions were obtained with CS3, 4, 5, and spatial resolutions of 2.0×2.0×10mm3, 1.8×1.8×10mm3, and 1.6×1.6×10mm3 for CS3 and 2.0×2.0×10mm3 for CS4 and 5. Results Significant differences in IQ, blurring, and aliasing were observed among acquisition protocols (p<0.05), but not in susceptibility artifacts (p=0.66). Higher CS levels slightly reduced IQ and increased aliasing and blurring. DL-denoising and higher spatial resolution methods improved sharpness without changing overall scores. Segment-wise T1 quantitative analysis revealed only minor differences, even in the presence of high-acceleration factors or increased spatial resolution. In most segments, two one-sided testing confirmed equivalence with low bias (-21 to +22ms). Scan-rescan experiments confirmed repeatability in healthy volunteers, while phantom experiments extended repeatability and inter-method stability to pathological T1 ranges. Conclusion Native T1 values remained stable across various CS acceleration factors, changes in spatial resolution, and application of denoising, with clinically negligible bias for tissue characterization. These findings, within a framework where total acquisition time is primarily determined by the number of inversion time (TI) images, support the use of CS to improve temporal resolution within each TI image, benefiting patients with arrhythmias or elevated heart rates, and also support the use of denoising and higher spatial resolution to improve image details. Overall, these results can enable patient-tailored T1 mapping protocols, improving the efficiency and diagnostic utility of quantitative CMR.

Topics

Humans; Deep Learning; Predictive Value of Tests; Reproducibility of Results; Male; Prospective Studies; Image Interpretation, Computer-Assisted; Female; Adult; Artifacts; Magnetic Resonance Imaging, Cine; Observer Variation

DOI: 10.1016/j.jocmr.2026.102726 · PubMed: 41997564

Cite this article

Perazzolo A, Vita CV, Scialò V, Gamal M, Bruno E, Chao TC. Customizing native T1 mapping: The effects of compressed sensing, deep learning-based denoising, and high-resolution on measurement of native myocardial T1. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102726

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Cardiovasc Magn Reson · Mar 20, 2026 · Research · Radiology & Imaging, Cardiology

Interactive deep learning for myocardial scar segmentation using cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Apr 16, 2026 · Research · Radiology & Imaging, Cardiology

Spatiotemporal deep learning for scar screening in cardiovascular magnetic resonance: Toward selective use of gadolinium

J Cardiovasc Magn Reson · Feb 17, 2026 · Research · Basic science · Radiology & Imaging, Digital Health & AI

Open-source pre-clinical image segmentation: mouse cardiac magnetic resonance imaging datasets with a deep learning segmentation framework

J Cardiovasc Magn Reson · Jan 29, 2026 · Research · Radiology & Imaging, Cardiology

Feasibility and reproducibility of semi-automated magnetic resonance angiography measurements of the thoracic aorta using commercial software

J Cardiovasc Magn Reson · Mar 12, 2026 · Research · Radiology & Imaging, Cardiology

Prognostic value of end-to-end deep learning assessment of myocardial scar and microvascular obstruction on late gadolinium enhancement cardiovascular magnetic resonance