Visual abstractsVisuals
ResearchOphthalmology Science · May 24, 2026

Deep Learning and Radiomics Assessment for Highly Myopic Glaucoma Detection Based on Fundus Photography

Luo M, Han W, Hu L, Zhou C, Zhu Y, Chen X, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose To investigate spatially distinctive features in fundus photographs of highly myopic glaucoma (HMG) by integrating radiomics and deep learning. Design Cross-sectional study. Participants Semi-automated optic disc segmentation was performed on 2000 images sourced from the Retinal Fundus Glaucoma Challenge Edition and Pathologic Myopia Challenge public data sets. We trained models with 628 images, including 217 cases of high myopia (HM), 221 cases of primary open-angle glaucoma (POAG), and 190 cases of HMG. An external validation set of 106 images was collected including 31, 36, and 39 fundus photographs from patients with HM, HMG, and POAG, respectively. Methods Semi-automated optic disc segmentation was performed by U-Net combined with manual delineation. Additionally, 5 regions of interest (ROIs) covering the optic disc and its surrounding region were explored. Fundus photography-based radiomics feature selection and optimization were conducted using random forest and support vector machine algorithms, which underwent fivefold cross-validation. Model performance was evaluated for radiomics, clinical, and combined models. An external validation set was used to evaluate the models performance, and we also examined radiomics features varied across glaucoma stages. Main outcome measures A total of 414 radiomics features were extracted from 5 regions of interest. We evaluated the model performance using accuracy, recall, precision, F1 score, and area under the receiver operating characteristic curve (AUROC). The Youden index was used to determine the cut-off value, and sensitivity and specificity were calculated. Results The U-Net-based optic disc segmentation reached a Dice Similarity Coefficient of 0.95. The radiomics model detected HMG from HM and POAG achieved the accuracies of 0.97 and 0.85, respectively. Both results exceeded the performance of the clinical model, which achieved 0.90 and 0.71. The top radiomics features achieved AUROC of 0.984 and 0.855 for HMG versus HM and HMG versus POAG in the external validation, respectively, including intensity features in the extra-optic nerve and textural features in the optic nerve. These features showed strong diagnostic capability when stratified by Youden values and exhibited independence from glaucoma progression. Conclusions The study combined U-Net and radiomics to delineate the spatial distribution biomarkers of HMG, establishing a quantitative classification model correlated with anatomical features. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101252 · PubMed: 42437115

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients