Visual abstractsVisuals
ResearchCirculation · Nov 8, 2025

Deep Learning-Based Continuous QT Monitoring to Identify High-Risk Prolongation Events After Class III Antiarrhythmic Initiation

Ansari RA, Bandyopadhyay S, Trivedi RK, Brennan KA, Liu X, Ganesan P, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Drug-induced QT prolongation after successful inpatient loading of class III antiarrhythmics may occur during routine outpatient care. Insertable cardiac monitors offer continuous signals but are limited by single-lead configuration. We hypothesized that a spatially aware deep learning system (3DRECON-QT) can reconstruct spatial information from a single lead vector to quantify QT/QTc and identify high-risk prolongation. Methods We developed 3DRECON-QT using a multitask encoder-decoder that ingests a 10-s single-lead signal, reconstructs 12 leads, and predicts QT/QTc. The model was developed using 12-lead ECGs with clinician-adjudicated QT/RR from a large health system and tested in an external center with different ECG hardware. Continuous monitoring performance was assessed in a public dofetilide-loading data set with serial ECGs. In a real-world cohort of outpatients on dofetilide or sotalol presenting to the hospital or emergency room for any reason, rates of ventricular arrhythmias and QT prolongation were assessed. Device validation was tested in patients with insertable cardiac monitor recordings paired with clinical 12-lead ECGs. Results 3DRECON-QT classified prolonged QTc from single-lead signals with area under the receiver operating characteristics curve, 0.942 (mean absolute error, 17.5 ms) in the internal test set and 0.943 (mean absolute error, 21.1 ms) externally. During continuous dofetilide monitoring, predictions correlated with ground truth (r, 0.851; mean absolute error, 17.8 ms; area under the receiver operating characteristics curve, 0.936 for prolonged QTc, 0.816 for ≥15% QTc rise). QTc prediction from true insertable cardiac monitor recordings showed r=0.824 and mean absolute error, 17.5 ms. In outpatients on class III antiarrhythmics (n=1676), 16.5% had high-risk QTc prolongation. Ventricular arrhythmia events were 3.97% versus 0.86% without prolongation (adjusted odds ratio, 4.24 [95% CI, 1.81-9.90]). 3DRECON-QT detected these events with area under the receiver operating characteristics curve 0.94 (F1 score, 0.60). Conclusions A single-lead, deep-learning approach can achieve guideline-level measurement accuracy, enable continuous QTc surveillance from nonstandard ECG vectors, and identify clinically meaningful outpatient QTc prolongation associated with a >4-fold increase in serious ventricular arrhythmias. This strategy may enhance safety monitoring after class III antiarrhythmic initiation and support targeted intervention.

Topics

Adult; Aged; Aged, 80 and over; Female; Humans; Male; Middle Aged; Anti-Arrhythmia Agents; Deep Learning; Electrocardiography; Retrospective Studies; Signal Processing, Computer-Assisted

DOI: 10.1161/CIRCULATIONAHA.125.077494 · PubMed: 41460938

Cite this article

Ansari RA, Bandyopadhyay S, Trivedi RK, Brennan KA, Liu X, Ganesan P. Deep Learning-Based Continuous QT Monitoring to Identify High-Risk Prolongation Events After Class III Antiarrhythmic Initiation. Circulation. 2025. doi:10.1161/CIRCULATIONAHA.125.077494

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Neuroeng Rehabil · Jun 4, 2026 · Research · Physical Medicine & Rehabilitation

SR-FSL: Sample reconstruction enhanced few-shot learning for real-time motor unit identification from surface electromyogram

Acad Emerg Med · Apr 30, 2026 · Research · Emergency Medicine

Initial 12 mg Versus 6 mg Adenosine for Supraventricular Tachycardia in the Emergency Department

JAMA · Dec 16, 2024 · Review · Cardiology

Atrial Fibrillation: A Review

J Am Heart Assoc · Jun 9, 2026 · Research · Cardiology

Genetic Investigation of Corrected QT Interval Sensitivity to Oral Bepridil Hydrochloride Hydrate in Patients With Atrial Fibrillation

Diabetes Obes Metab · Mar 19, 2026 · Review · Endocrinology & Diabetes

Advances in Electrocardiogram-Based Non-Invasive Blood Glucose Monitoring Technology