Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Jan 20, 2026

Deep learning motion correction of quantitative stress perfusion cardiovascular magnetic resonance

Schueler NIP, Wong NCK, Crawley RJ, Pluim JPW, Chiribiri A, Scannell CM
Radiology & ImagingCardiologyDigital Health & AIAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Quantitative stress perfusion cardiovascular magnetic resonance (CMR) is a valuable tool for assessing myocardial ischemia. Motion correction is a crucial step in automated quantification pipelines, especially for high-resolution pixel-wise mapping. Established methods for motion correction, based on image registration, are computationally intensive and sensitive to changes in image acquisitions, necessitating more efficient and robust solutions. Methods This study developed and evaluated an unsupervised deep learning-based motion correction pipeline. Based on a previously described approach, it corrects motion in three steps while using (robust) principal component analysis to mitigate the effects of the dynamic contrast. The time-consuming iterative registration optimizations are replaced with an efficient one-shot estimation by trained deep learning models. The pipeline aligns the perfusion series and includes auxiliary images series as follows: the low-resolution, short-saturation preparation time arterial input function series and the proton density-weighted images. The deep learning models were trained and validated on multi-vendor data from 201 patients, with 38 held out for independent testing. The performance was evaluated in terms of the temporal alignment of the image series and the derived quantitative perfusion values in comparison to a previously established optimization-based registration approach. Results The deep learning approach significantly improved temporal smoothness of time-intensity curves compared to the previously published baseline (p<0.001). Temporal alignment of the myocardium (based on automated segmentations) was similar between methods and significantly improved for both as compared to before registration (mean (standard deviation) Dice = 0.92 (0.04) and Dice = 0.91 (0.05) (respectively) vs Dice = 0.80 (0.09), both p<0.001). Quantitative perfusion maps were also smoother, indicating a reduction of motion artifacts, with a median (interquartile range) standard deviation of 0.52 (0.39) ml/min/g in myocardial segments, than before motion correction and improved compared to the baseline method (0.55 [0.44] mL/min/g). Processing time was reduced by a factor of 15 for a representative image series using the deep learning approach in comparison to the iterative method. Conclusion The deep learning approach offers faster and more robust motion correction for stress perfusion CMR, improving accuracy for the dynamic contrast-enhanced data and the auxiliary images. It was trained with multi-vendor data and different acquisition sequence implementations, so, as well as enhancing efficiency and performance, it could facilitate broader clinical use of quantitative perfusion CMR.

Topics

Deep Learning; Humans; Myocardial Perfusion Imaging; Image Interpretation, Computer-Assisted; Predictive Value of Tests; Reproducibility of Results; Coronary Circulation; Perfusion Magnetic Resonance Imaging; Time Factors; Vasodilator Agents; Female; Male

DOI: 10.1016/j.jocmr.2026.102697 · PubMed: 41571054

Cite this article

Schueler NIP, Wong NCK, Crawley RJ, Pluim JPW, Chiribiri A, Scannell CM. Deep learning motion correction of quantitative stress perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102697

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Cardiovasc Magn Reson · Jan 7, 2026 · Research · Radiology & Imaging, Cardiology

Needle-free myocardial blood flow and reserve quantification using artificial intelligence-enhanced coronary sinus flow magnetic resonance imaging with exercise cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Aug 8, 2025 · Guideline · Radiology & Imaging, Cardiology

Society for cardiovascular magnetic resonance expert consensus statement on quantitative myocardial perfusion cardiovascular magnetic resonance imaging

Rheumatology · Apr 23, 2026 · Research · Rheumatology, Cardiology

Coronary microvascular dysfunction in systemic sclerosis: insights from PET-derived myocardial flow reserve

J Cardiovasc Magn Reson · Mar 20, 2026 · Research · Radiology & Imaging, Cardiology

Interactive deep learning for myocardial scar segmentation using cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Apr 16, 2026 · Research · Radiology & Imaging, Cardiology

Spatiotemporal deep learning for scar screening in cardiovascular magnetic resonance: Toward selective use of gadolinium