Visual abstractsVisuals
ResearchAmerican Journal of Emergency Medicine · Jan 3, 2026

Deployment of automated external defibrillators by a supermarket chain

Scheppke KA, Pepe PE, Crowe RP, Jiang J, Scheppke EK, McCoy SA
Emergency MedicineAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Objective Automated external defibrillator (AED) installation has become commonplace in various public locations. However, AED retrievals involving actual shocks may still be very infrequent in many settings despite significant initial/ongoing costs for equipment acquisition, pad/battery expiry replacements and initial/refresher training for designated rescuers. The purpose here was to track frequencies of AED/CPR applications and shocks delivered following AED installations and related employee training throughout a multi-state retail store chain. Design Prospective 92-month observational study conducted across a large retail chain to document frequencies of AED device retrievals/applications, CPR performance, shocks delivered, and respective patient and scene characteristics. Setting 1358 retail stores and two-dozen warehouses/offices located in multiple states. Subjects Persons collapsing with possible cardiopulmonary arrest on corporate properties. Interventions AED installation and on-going training of employees in CPR/AED use. Results Among 396 reported AED retrievals/applications (>4/month), 75 % occurred inside stores and the remainder in parking lots/sidewalks/other venues. Among these, 294 persons (ages 1-93 years; 74 % men) received basic CPR and/or AED shocks (>3 cases/month), performed most often by store employees. CPR-patient median age was 60 years (IQR:45-70) for men and 58 (IQR:38-68) for women. AEDs delivered 157 shocks during 112 events (>1 case/month); 71 % involved one shock, 20 % two, 9 % three and one involved four shocks. Documented ages for shocked patients (80 % men) ranged 32-90 years with men's median age 62 (IQR:55-70) and women's 61 (IQR:55-65). In one state's retrospective sub-analysis of shockable cases, hospital outcome records were matched to 37 patients with the majority (at least 19 confirmed) surviving to successful hospital discharge. Conclusions For this multi-state retail chain, AED installation and employee CPR/AED training appeared to be well-justified considering that AEDs were retrieved/applied frequently systemwide, quite often involving defibrillatory shocks that were associated with survival for many patients. Investigators encourage comparable businesses to adopt/study similar employee-based programs nationwide.

Topics

Humans; Defibrillators; Prospective Studies; Female; Male; Cardiopulmonary Resuscitation; Middle Aged; Aged; Adult; Out-of-Hospital Cardiac Arrest; Adolescent

DOI: 10.1016/j.ajem.2025.12.033 · PubMed: 41518723

Cite this article

Scheppke KA, Pepe PE, Crowe RP, Jiang J, Scheppke EK, McCoy SA. Deployment of automated external defibrillators by a supermarket chain. Am J Emerg Med. 2026. doi:10.1016/j.ajem.2025.12.033

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Emerg Med J · Sep 18, 2026 · Review · Emergency Medicine

Endovascular resuscitation: an expert practice review

Am J Emerg Med · Jun 16, 2026 · Review · Emergency Medicine

Crowdsourcing technologies for out-of-hospital cardiac arrest response: A scoping review

Emerg Med J · Aug 20, 2026 · Research · Emergency Medicine

What factors delay initiation of bystander CPR in out-of-hospital cardiac arrest? Results from an analysis of 200 recorded ambulance calls

Acad Emerg Med · Apr 13, 2026 · Research · Emergency Medicine

Determining Access for a City-Wide Extracorporeal Cardiopulmonary Resuscitation (ECPR) Initiative Using Geospatial Analysis

Am J Emerg Med · Nov 10, 2025 · Randomized trial · Emergency Medicine

The NASA Task Load Index in simulated cardiopulmonary resuscitation