ResearchJournal of NeuroEngineering and Rehabilitation · Jul 2, 2026
Determination of cut-off points for the Move4 accelerometer and assessment of energy expenditure in children and adolescents aged 6-16 years using manual wheelchairs: a validation and calibration study
Seemüller S, Reimers AK, Meixner B, Engel F, Beck F
Abstract
Background
The present study aimed to determine activity intensity and validate the Move4 accelerometer and derive cut-off points to accurately classify wheelchair-based physical activity (PA) in children and adolescents. Methods
A calibration and validation study with a test-retest design was performed in 24 children and adolescents (mean age 9.9 ± 3.2 years; 50% girls) using manual wheelchairs. Participants used a manual wheelchair as their primary mode of mobility and were able propelling the wheelchair independently. Participants completed standardized activities while wearing Move4 sensors at the wrist, upper arm, and chest. In a subsample of 7 children and adolescents, energy expenditure was recorded using portable metabolic cart. Mean Amplitude Deviation (MAD) and Movement Acceleration Intensity (MAI) were processed to derive cut-off points for sedentary, light, moderate, and vigorous PA using CART models, and validity was assessed via Metabolic Equivalent (MET) and heart-rate responses. Results
Both MAD and MAI values increased systematically across activity intensities, supporting good criterion validity. MET values showed progression from sedentary to vigorous tasks. Intensity-specific cut-off points were successfully established for all sensor placements, with consistently higher thresholds for MAI. Sensitivity and specificity analyses indicated the most balanced performance for the upper arm (MAD) and chest (MAI). Test-retest comparisons showed greater variability for MAD-based cut-offs, whereas MAI thresholds demonstrated higher stability, with deviations of approximately 4-5%. Conclusions
While both MAD and MAI validly reflected PA intensity, MAI showed greater temporal stability and test-retest robustness. These findings support the use of accelerometery for classifying PA in children and adolescents using wheelchairs and underscore the importance of selecting appropriate metrics and sensor positions.
Topics
Humans; Female; Child; Adolescent; Energy Metabolism; Accelerometry; Wheelchairs; Male; Calibration; Reproducibility of Results
DOI: 10.1186/s12984-026-02085-5 · PubMed: 42393793
Spotted a mistake? Suggest a correction
More in Physical Medicine & Rehabilitation
Feasibility, safety, and preliminary effects of haptic cane-assisted gait training in chronic hemiparetic stroke: a pilot randomized crossover trial
ResearchJ Rehabil Med · Nov 18, 2026 · Physical Medicine & Rehabilitation
Satisfaction with hospital-based outpatient rehabilitation in people with Parkinson's disease and its association with life satisfaction and health-related quality of life: a longitudinal national register study
Randomized trialJ Neuroeng Rehabil · Nov 12, 2026 · Physical Medicine & Rehabilitation
Frequency-specific cortical swallowing-network responses following neuroengineering-guided individualized multichannel tDCS
ResearchArch Phys Med Rehabil · Nov 11, 2026 · Physical Medicine & Rehabilitation
Physiological responses during high intensity interval training and moderate intensity continuous training in patients attending early cardiac rehabilitation
XR serious games for phantom limb pain, neurofunctional recovery, and prosthetic adoption: a systematic review