Development and Analytical Validation of a Multiplex LC-MRM-MS-Based Reference Measurement Procedure for Apolipoprotein A-I and Btotal Quantification in Serum

Diederiks NM, Romijn FPHTM, van Neer NJM, Pieterse M, Dittrich J, Ceglarek U, et al
Pathology & Laboratory MedicineAdult
Read the full paper free at the publisher ↗

Abstract

Background Medical results from regulated in vitro diagnostic devices should be accurate. The previous reference measurement procedures (RMP) for apolipoprotein A-I (ApoA-I)/apolipoprotein B total (ApoBtotal) standardization are no longer functional. A new RMP aligned with ISO15193:2009 and calibration models of ISO17511:2020 was developed using multiplex liquid chromatography-multiple reaction monitoring-mass spectrometry (LC-MRM-MS) for quantifying ApoA-I and ApoBtotal in serum. Methods Serum samples underwent reduction, alkylation, lysyl endopeptidase/trypsin digestion, and proteotypic peptide purification. Optimal retention times, precursor/fragment ion m/z were selected using an Agilent-1290 ultra-high-performance liquid chromatography coupled to a 6495C triple-quadrupole mass spectrometer. Calibrators were indirectly traceable to WHO/IFCC SP1-01/SP3-08 (ApoA-I/ApoBtotal) via the RMP, with propagated measurement uncertainty (MU), supported by replicate SP1-01/SP3-08 measurements across independent batches. Validation followed ISO15193:2009 and included linearity, recovery, uncertainty, precision, stability, preanalytical conditions, carryover, limit of blank (LoB), limit of detection (LoD), limit of quantification (LoQ), and comparability. Results Linearity was confirmed from 0.10 to 2.97 g/L and 0.27 to 3.83 g/L (ApoA-I/ApoBtotal), with Conclusions This LC-MRM-MS-based RMP for ApoA-I and ApoBtotal provides a next-generation RMP succeeding the former ELISA-based RMP. Certification of commercially available ApoA-I/ApoBtotal tests will enable continued global standardization of ApoA-I/ApoBtotal measurements, while preserving traceability of test results to the former WHO-IFCC reference materials within maximum allowable uncertainty.

Topics

Humans; Apolipoprotein A-I; Liquid Chromatography-Mass Spectrometry; Reference Standards; Apolipoproteins B; Calibration; Chromatography, High Pressure Liquid; Chromatography, Liquid; Reproducibility of Results; Mass Spectrometry

DOI: 10.1093/clinchem/hvag041 · PubMed: 42201254

Spotted a mistake? Suggest a correction

More in Pathology & Laboratory Medicine

ResearchMod Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine

Tumor-selective overexpression of five receptors found in triple-negative breast cancer

Intra-Patient Cell-Surface Receptor Normalization Refines TNBC Biomarker Profiling for Precision Oncology

ResearchMod Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine

CD40 expression differentiates Hodgkin lymphoma from anaplastic large cell lymphoma

CD40 expression is highly sensitive and specific for differentiating between classic Hodgkin lymphoma and ALK-negative anaplastic large cell lymphoma

ResearchMod Pathol · Nov 12, 2026 · Pathology & Laboratory Medicine

Deciphering Benign and Malignant Perineuriomas: A Comparative Epigenomic and Genomic Study With Hybrid and Malignant Peripheral Nerve Tumors

ResearchPediatricMod Pathol · Nov 12, 2026 · Pathology & Laboratory Medicine

Pediatric-type Follicular Lymphoma Shows Unique Immunogenetic Features With Lack of Acquired N-glycosylation Sites

ResearchMod Pathol · Nov 12, 2026 · Pathology & Laboratory Medicine

Pilomatrix-like high-grade endometrioid carcinomas have distinct molecular features

Pilomatrix-like High-Grade Endometrioid Carcinoma in the Female Genital Tract: A Single-Institution Clinicopathologic Analysis of 15 Cases