ResearchChest · Jul 28, 2026
Development and Multicenter Validation of a Breathomics-Based Triage Tool for Lung Cancer: A Prospective Study of 5,214 Participants
Qin J, Sun M, Li X, Duan X, Li Y, Ma H, et al
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
The inherent false-positive rate of CT imaging necessitates efficient, noninvasive triage tools to distinguish lung cancer from benign mimics, thereby streamlining early detection and mitigating unnecessary invasive procedures. Research question
Can a machine learning-derived, molecularly resolved breathomics prediction model effectively triage patients with radiologically detected pulmonary abnormalities in a real-world symptomatic cohort? Study design and methods
In this large-scale, prospective, multicenter diagnostic accuracy study, we enrolled 5,214 symptomatic patients with radiological lung abnormalities at two campuses. Participants were allocated into a discovery cohort (n = 4,669) and a geographically independent external validation cohort (n = 545). Exhaled volatile organic compounds were analyzed by high-throughput proton-transfer-reaction time-of-flight mass spectrometry. A machine learning model integrating a specific volatile organic compound signature with clinical factors was developed, locked, and validated blind in the external cohort. Results
The integrated model achieved an area under the receiver operating characteristic curve (AUC) of 0.891 (95% CI, 0.864-0.915) in the independent internal testing set. In the independent external validation, the model maintained robust performance (AUC, 0.850; 95% CI, 0.805-0.890). In this validation cohort, applying the prespecified "rule-out" threshold, the model achieved a sensitivity of 93.1% (95% CI, 90.5%-95.4%), with an overall specificity of 55.9% and negative predictive value of 71.0%. Importantly, in the intended-use pulmonary medicine subgroup (n = 155), the sensitivity was 91.4%, with specificity and negative predictive value reaching 55.8% and 89.0%, respectively. Subgroup analyses confirmed consistent efficacy across diverse clinical scenarios, notably maintaining robust accuracy in detecting early-stage disease (AUC, 0.849). Interpretation
This study represents the largest prospective validation of a mass-spectrometry-based breath test to date. The validated prediction model holds potential to serve as a robust, noninvasive triage tool. Its integration into the diagnostic pathway shows promise for enhancing efficiency and reducing unnecessary biopsies, particularly in respiratory outpatient settings.
DOI: 10.1016/j.chest.2026.06.067 · PubMed: 42521150
Spotted a mistake? Suggest a correction
More in Pulmonology
ReviewEur Respir J · Nov 23, 2026 · Pulmonology
Solving an enigma: the BMP-9/10 axis as a key regulator of pulmonary vascular resilience
Needle aspiration versus intercostal chest drain for secondary spontaneous pneumothorax (the PRINCE-SSP trial): a pragmatic, open-label, multicentre, non-inferiority, randomised controlled trial
Safety and efficacy of inhaled itraconazole in adults with asthma and allergic bronchopulmonary aspergillosis (PUR1900-ABPA): a randomised, double-blind, parallel group, placebo-controlled, multicentre, phase 2 trial
ResearchChest · Nov 21, 2026 · Pulmonology
ResearchChest · Nov 21, 2026 · Pulmonology
Combination acetazolamide and supplemental oxygen markedly improves ventilatory control instability and OSA severity