Visual abstractsVisuals
ResearchJACC: Advances · Jan 20, 2026

Device-Removal, Reinfection, and Mortality After Staphylococcus aureus Bacteremia in Patients With Cardiac Implantable Electronic Devices

Bengtsen KH, Le MV, Haugan K, Philbert BT, Johansen JB, Torp-Pedersen C, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background In case of Staphylococcus aureus bacteremia (SAB), complete cardiac implantable electronic device (CIED) removal is advised by the European Heart Rhythm Association. Objectives The objective of the study was to estimate clinical outcomes after SAB in the Danish CIED carriers. Methods We conducted a nationwide register-based cohort study including all patients with SAB after CIED implantation between 2000 and 2020. Cumulative incidence of device removal, SAB reinfection, and all-cause mortality were estimated and compared to sex and age-matched non-CIED controls with SAB. Landmark analysis at the time of hospital discharge estimating mortality and reinfection according to CIED removal status in surviving patients was conducted. Results In total, 1,816 patients with CIED and SAB and 9,080 matched controls were included in the study (median age 77.5 years, 73.0% males). Thirty-day all-cause mortality was 34.0% (95% CI: 31.8%-36.2%) in patients with CIED and 31.0% (95% CI: 30.0%-31.9%) in controls (P = 0.019, adjusted HR: 1.11 [95% CI: 1.02-1.22]). Device removal within 30 days was performed in 286 patients (15.8%). The landmark analysis showed significantly lower 180-days cumulative incidence of SAB reinfection and all-cause mortality in patients undergoing device removal compared to those with retained CIEDs (reinfection: 2.5% vs 5.5%; mortality: 7.8% vs 31.2%). Patients who underwent CIED removal were younger and had less comorbidity compared to those with retained CIEDs. Conclusions The Danish CIED carriers had slightly higher 30-day all-cause mortality after SAB compared to matched controls. Only a minor selected proportion underwent device removal after SAB diagnosis and, after initial survival, these patients had lower 180-days reinfection rates and mortality compared to patients with retained devices.

DOI: 10.1016/j.jacadv.2025.102480 · PubMed: 41564732

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology