Visual abstractsVisuals
Meta-analysisJACEP Open · Feb 21, 2025

Diagnostic Performance of Monocyte Distribution Width for the Detection of Sepsis: A Systematic Review and Meta-Analysis

Eisinger GJ, Hosler Q, Crouser ED, Herman DD
Emergency MedicineInfectious DiseaseCritical CareAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives To aggregate literature on the diagnostic performance of monocyte distribution width (MDW) for sepsis detection among adults in the emergency department and inpatient settings. Methods We searched the MEDLINE, EMBASE, SCOPUS, and Cochrane databases for studies evaluating MDW for sepsis diagnosis in adults in the hospital setting through October 19, 2024. Two authors (G.E. and Q.H.) independently performed eligibility assessment, data extraction, and risk of bias assessment. We evaluated performance for sepsis-2 and sepsis-3 separately and applied separate diagnostic thresholds depending on the anticoagulant used in blood collection. Data were pooled using a random-effects model. We performed multiple sensitivity analyses to evaluate the stability of our findings. Results Twenty-five observational studies comprising 39,041 patients were included. The area under the summary receiver operating curve (AUC) was 0.82 (95% CI, 0.78-0.85) for both sepsis-2 and sepsis-3. Sensitivity and specificity were 0.79 (95% CI, 0.74-0.83) and 0.7 (95% CI, 0.61-0.78) for sepsis-2 and 0.83 (95% CI, 0.78-0.88) and 0.64 (95% CI, 0.55-0.71) for sepsis-3. The threshold-independent weighted-average AUC was 0.76 (SD, 0.1) for sepsis-2 and 0.77 (SD, 0.07) for sepsis-3. The aggregate negative predictive value was 94% for sepsis-2 and 96% for sepsis-3. We observed similar performance across all sensitivity analyses. We assessed the overall quality of evidence to be low. Conclusions MDW performs similarly to other biomarkers such as procalcitonin for the diagnosis of sepsis, with the unique advantage of rapid availability as part of routine testing.

DOI: 10.1016/j.acepjo.2025.100073 · PubMed: 40084266

Cite this article

Eisinger GJ, Hosler Q, Crouser ED, Herman DD. Diagnostic Performance of Monocyte Distribution Width for the Detection of Sepsis: A Systematic Review and Meta-Analysis. JACEP Open. 2025. doi:10.1016/j.acepjo.2025.100073

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Emergency Medicine

J Med Internet Res · Nov 23, 2026 · Meta-analysis · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

BMJ Med · Nov 18, 2026 · Research · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Am J Emerg Med · Nov 13, 2026 · Research · Emergency Medicine, Hematology

ED red blood cell transfusion linked to longer hospital stays in severe anemia

J Med Internet Res · Nov 13, 2026 · Research · Digital Health & AI, Emergency Medicine

Physicians often intend to act on false information in AI-generated abstracts

Am J Emerg Med · Nov 12, 2026 · Research · Emergency Medicine, Neurology

Serum lactate levels differed across neurologic emergencies in emergency patients